background image

2

EXP9

VIDEO

AUDIO

L

R

ZONE IR INPUTS

ZONE  OUTPUTS

ZONE IR OUTPUTS

7

8

9

10

11

12

®

SYLMAR, CA • MADE IN U.S.A.

POWER

POWER
SUPPLY

EXP9

NINE ZONE EXPANDER

+12V

GND

STATUS

IR IN

13

14

15

ZONE OUTPUTS

1

2

3

6

7

8

4

5

Fig. 2

  EXP9 Panel Features and Functions (shown with all nine zones installed)

EXP9 PANEL DESCRIPTIONS

1. ZONE IR INPUTS.  Each zone of the EXP9 is individually controlled through these ports.  As with the

ZPR68-10, three of the four screw terminals on each plug-in connector are for connection, via the
standard Xantech 3-wire bus, to any Xantech IR receiver, keypad (except Model 598), or controller.
The remaining terminal, STATUS, provides a control output of +12 volts that turns on and off with a
zone INPUT (ON) and OFF commands to drive status indicators and/or the voltage sensing ports of
power amplifiers or AC power strips.  The connector markings are defined as follows:  +12 VGND,
STATUS and IR IN.

2. ZONE IR OUTPUTS.  These nine 3.5mm mono mini jacks are for the connection of emitters to control

components dedicated to any zone.

3. Zone IR Indicator LED's.  These nine LED's, one for each zone, flash to indicate when a zone is

receiving IR commands from an IR receiver, keypad, etc.

4. I/O PORT.  These multi-pin connector jacks provide an input/output port.  This allows the EXP9 to be

linked with a ZPR68-10, via two large ribbon cables (included), to provide up to 15 zones of operation.
The EXP9 includes 9 slots, allowing zone XCARDs (expansion PCB cards) to be added, one by one
in the field, or purchased already installed from the factory, for zones 7 through 15.

5. STATUS  DRIVER PINS.  These pins allow connection to STATUS LED's located in an optional rack

mount panel.  The LED's are driven from the individual status lines of each zone (9 total for the EXP9),
allowing visual indication of zone ON/OFF condition at the front of the rack panel.

6. ZONE OUTPUTS.   The ZONE OUTPUTS consist of up to nine sets of audio/video RCA type jacks

- one set for each zone.  The L and R AUDIO jacks are connected to the appropriate Left & Right input
jacks on a main power amplifier for the zone and the VIDEO  jack to the composite Video input on a
zone TV monitor or modulator.  Any source connected to the SOURCE INPUTS on a connected
ZPR68-10 can be switched to these ZONE OUTPUTS when the zone receives an RC68 INPUT
command at the ZONE IR INPUTS.

7. POWER SUPPLY Connector.  6-Pin DIN jack permits connection of a high current multi-voltage AC

power supply (included with each EXP9).

Summary of Contents for EXP9

Page 1: ...or in field expansion Whenreceivedfromthefactory unusedzoneopeningsarecoveredfromunderneathwithindividualcover plates These are removed as needed when additional zone XCARDs are installed in the field...

Page 2: ...s receiving IR commands from an IR receiver keypad etc 4 I O PORT These multi pin connector jacks provide an input output port This allows the EXP9 to be linked with a ZPR68 10 via two large ribbon ca...

Page 3: ...lly align the holes in the top cover with the jacks and the LEDs on all the PCB s before pressingitdownintoplaceandreplacingthescrews CONNECTING THE EXP9 TO A ZPR68 10 To make the necessary con nectio...

Page 4: ...es in the top cover with the jacks and the LEDs on all the PCB s before pressing it down into place and replacing the screws INSTALLATION To install the ZPR68 10 EXP9 combination into the application...

Page 5: ...dd up the current demands for the devices used in the system If the total current exceeds 1 8 A it is then necessary to use a 782 00 power supply to separately power the V or 12V terminals of the addi...

Page 6: ...a system that is so extensive that the total current exceeds the 1 8 A limit of the EXP9 by more than 1000 mA use two 782 00 s connected so that two separate 12V DC rails are created Connect two group...

Page 7: ...a different number The drawback to this solution is that you would need dedicated learning remotes if used for the rooms having the different IR Code Groups 4 I have two or more zone dedicated same br...

Page 8: ...Max Total Current Available From 12V STATUS Terminals 1 8 A Power Requirements 14V 0 14V AC 2 7 A 8V 0 8V AC 0 7 A Multi Voltage Power supply included Gold Plated RCA type phono jacks All A V inputs...