OPERATION INSTRUCTION

SETUP AMPLIFIER ID

DEVICE NO.

#

1

Amplifier ID

Then, turn CHA to change the amplifier ID from 1 to 255.
Press CHA button again and save the setting.

C.

 NOISE GATE SETUP

Under the menu SETUP AMPLIFIER ID, press the CHA button
again for about 3 seconds and then the LCD shows as follows:

NOISE  GATE SETUP

ON

E.

 LOAD PROGRAM

Press the CHB button for about 3 seconds, the LCD shows as follows:

Then, turn CHA to select one program (1-21).
Press CHB button again, save the setting and load the selected
program. At the same time, the LCD shows:

LOADING ...

Several seconds later, the LOADING is finished and the system
return the menu.

NOTE:

1.

 Among 21 programs, No.21 is not used under the online

mode without PEQ, XOVER and DELAY. The other 20 programs
can be saved and recalled on the online mode.

2.

 The volume is mute automatically after every LOAD PROGRAM.

3. 

When the system switches from the online mode to the offline,

the system can load the program that is saved under the online
mode. At the same time, the volume is automatically mute.

OFF LINE MODE

Switch on the power, the system accesses the OFFLINE mode.

A.

 ADJUST THE VOLUME

Turn CHA/CHB button to adjust the input level of CHA/CHB.
Pressing the CHB button for 1 second, both channels will be
muted.

B.

 SETUP THE AMPLIFIER ID

Press CHA button for about 3 seconds, the LCD shows as
follows:

LOAD PROGRAM P: 11

NO PEQ

+

XOVER

+

DELAY

Program Number

Program Name

F.

 SETUP VOLUME PROTECT

Under the menu of load program, press the CHB button again
for about 3 seconds and then the LCD shows as follows:

VOLUME MUTE PROTECT

AUTO MUTE: ON

AUTO MUTE: ON. When the power is on, the volume of CHA/CHB
is MUTE automatically.
AUTO MUTE: OFF. When the power is on, the volume of
CHA/CHB comes to the setting when power was off last time.

G.

 SETUP GAIN LINK

Under the menu of load program, press the CHB button two

times again for about 3 seconds and then the LCD shows as

follows:

GAIN LINK SETUP

ON

Turn the CHB button to switch on/off gain link. Then, press the
CHB button again to save the setting.
GAIN LINK: ON. the volume of CHA/CHB is linked.
GAIN LINK: OFF. the volume of CHA/CHB is independent.

H.

 SECURITY SETUP

Under the menu of load program, press the CHB button three
times again for about 3 seconds and then the LCD shows as
follows:

SECURITY SETUP

Then, press the CHB button again to enter the security password
to lock all the functions of the DSP amplifier.

Turn the CHB button to switch on/off AUTO MUTE. Then, press
the CHB button again to save the setting.

Turn the CHA button to switch on/off the noise gate. Then, press
the CHA button again to save the setting.
NOISE GATE: ON.
It insert a noise gate on the output of CHA/CHB automatically.
NOISE GATE: OFF. The noise gate is not inserted.

X

-

T

R

E

M

E

4

X

-TREME

via Monti Urali, 31 - 42029 Reggio Emilia (Italy) • ph. +39 - 0522 - 557735 • fax +39 - 0522 - 393733 • e-mail: [email protected]

D.

 SUB ADDRESS

Under the menu NOISE GATE SETUP, press the CHA button
again for about 3 seconds and then the LCD shows as follows:

Turn the CHA button to change the Sub Address number.
Then, press the CHA button again to save the setting.

FIRMWARE: DSP VS_1.0

SUB  ADDRESS: 423

Summary of Contents for XT2000

Page 1: ...X TREME Amplifiers Stereo DSP Power Amplifiers X T R E M E X TREME via Monti Urali 31 42029 Reggio Emilia Italy ph 39 0522 557735 fax 39 0522 393733 e mail info x tremeaudio com ...

Page 2: ...n Well designed signal generator sin wave and white noise S PDIF input output option Matrix control up to 255 units controlled by selecting address code Save and recall all parameters via PC parallel port 3 band PEQ limiter threshold attack time and release time adjusted delay max 8ms phase invert input gain control Two crossover range 20Hz 20kHz Crossover frequency adjusted Slope 6 12 18 24 and 4...

Page 3: ...he amplifier see technical specification Please use speaker cable only normally provided with one red and one black wire Do not use the signal cable normally used for microphone and audio equipment 3 Earthed ON FLOATING Separate the signal earth from the chassis Using this selector to break earth loops which can form when several units are connected 4 Power AC 220V 10 50 60Hz 5 Air vents Note the ...

Page 4: ...Under the menu of load program press the CHB button again for about 3 seconds and then the LCD shows as follows VOLUMEMUTEPROTECT AUTOMUTE ON AUTO MUTE ON When the power is on the volume of CHA CHB is MUTE automatically AUTO MUTE OFF When the power is on the volume of CHA CHB comes to the setting when power was off last time G SETUP GAIN LINK Under the menu of load program press the CHB button two...

Page 5: ...operation of DSP6 software please refer to the online help of it PC SOFTWARE s t e r e o D S P p o w e r a m p l i f i e r amplifiers X T R E M E 5 X TREME via Monti Urali 31 42029 Reggio Emilia Italy ph 39 0522 557735 fax 39 0522 393733 e mail info x tremeaudio com Select one device number 1 255 If this number is the same as the amplifier ID the LCD shows as follows MENU COMMAND File menu New cre...

Page 6: ...ay Click the Delay button and then the delay unit and delay time can be set Max delay 8ms 5 Phase Click the 180 check box to select The reverse phase 0 180 6 Limiter Click the Limiter button and then the threshold hold time attack time and release time can be adjusted Used for protecting the system X T R E M E 6 X TREME via Monti Urali 31 42029 Reggio Emilia Italy ph 39 0522 557735 fax 39 0522 393...

Page 7: ...s normally made up of two wires usually with a greater cross section the use of unscreened cables could in fact cause annoying buzzes and background noise We therefore always suggest the use of balanced cables for microphones and line units whenever possible To connect the amplifier to the loudspeaker enclosures always use only power cables not signal cables as in the latter case in fact the power...

Page 8: ...llowed 1 Read all the SAFETY INSTRUCTIONS before using the product 2 This product must be earthed If it has malfunction or breaks down grounding provides a path of least resistance for electric current to reduce risk of electric shock This product is equipped with a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properl...

Reviews: