74
75
Wi-Fi Communicating Current < 120 mA (avg.)
Coverage Area
20-40 m
Best Operating Temperature
4-40 °C
Relative Humidity in Operation ≤ 85% (non-condensing)
Sound Pressure
≥ 85 dB at 3 m @ 3.2 ± 0.3 kHz pulsating
alarm
Hush Time
About 9 minutes
App
TuyaSmart app (Android and iOS
supported)
Radio Frequency (Wi-Fi)
2.4 GHz
Wireless Protocol
IEEE 802.11b/g/n
Remark!
Battery life has been calculated based on the balance between weekly
tests and standby mode. If these conditions change to an alarm condition, the
battery life decreases accordingly. If the unit has been in alarm mode for a long
time and/or is severely damaged by smoke, the unit is considered to have saved
lives and then the warranty cannot be invoked. The warranty does not cover
batteries.
Maintenance
To keep your smoke alarm in good working order, follow these simple steps:
1. Verify that the unit's alarm sound and indicator are working properly by
testing the unit once a week.
2. As a minimum, your smoke alarm should be cleaned once every three
months: Remove the unit from the ceiling and clean the alarm cover and
vents with your vacuum cleaner, fi tted with the soft brush attachment to
remove dust and dirt.
3. Never use detergents or other solvents to clean the unit.
4. Avoid spraying air fresheners, hair spray or other aerosols near the alarm.
5. Do not paint the unit. Paint will seal the vents and interfere with the
sensor’s ability to detect fi re.
6. Never attempt to disassemble the unit or clean inside. Doing so will void
your warranty.
7. When removed, place the smoke alarm back in its proper location as soon
as possible, to assure continuous protection from fi re.
8. When household cleaning supplies or similar contaminants are used, the
area should be ventilated.
Troubleshooting
Problem
Solution
Your smoke alarm does not
sound during testing.
• Please check whether the alarm is properly
attached to the mounting bracket.
• Make sure you push the central test
button fi rmly.