background image

Test all 

interconne

cted units 

 

The red LED indicator flashes 

rapidly. 

 

Continuous 

beeping until 

you release the 

TEST/HUSH 

button. 

 

Initiatingunit. 

Hold down the TEST/HUSH 

button on one unit in the 

network.   

 

The red and green LEDsflash 

sequentially. 

Other interconnected alarms 

in the network. 

Silence Mode 

 

 

The red LED indicator flashes 4 

times every 5.8 seconds. 

 

 

None. 

CO silence mode: After 9 

minutes, the unit will exit 

silence mode.

 

 

The yellow LED indicator flashes 

once every 60 seconds. 

None. 

Silence mode during low 

battery: After 10 hours, the 

unit will exit silence mode. 

 

The yellow LED indicator flashes 

3 times every 60 seconds.

 

None. 

Silence mode during the 

end of the cycle: After 22 

hours, the unit will exit 

silence mode. 

 

The green LED indicator flashes 3 

times.

 

None. 

Exiting silence mode. 

Low Battery 

 

 

 

Display alternates between "Lb" 

and the current CO level. The 

yellowLED indicator flashesonce 

every 60 seconds. 

1 quick beep 

every 60 

seconds. 

 

The batterymust be replaced 

immediately. 

 

Fault 

 

The yellow LED indicator flashes 

twice every 60 seconds. 

2 beeps 

every 60 

seconds. 

 

Please clean youralarm 

and see if it is working 

normally. If "Err" 

continues 

to display, the unit has 

malfunctioned and must 

be replaced immediately. 

End of Life 

 

The yellow LED indicator flashes 3 

times every 60 seconds. 

 

3 quick 

beepsevery 60 

seconds. 

Replace the 

unitimmediately. 

 

Summary of Contents for Link+ CO03D-W

Page 1: ...X SENSE CO03D W Wireless Interlinked Carbon Monoxide Alarm...

Page 2: ...lectrochemical sensor designed for domestic use Please note that this device does not detect smoke heat flames or anyhazardous gas other than carbon monoxide even though carbonmonoxide can be generate...

Page 3: ...5 V AA Batteries 2 Screws 2 Anchor Plugs 1 User Manual 2 Carbon Monoxide Safety Stickers Product Features LCD Display Fault Low Battery Indicator Yellow LED Alarm Indicator Red LED Power Indicator Gr...

Page 4: ...programmed to sound an alarm at the following CO concentrations within the time periods listed 70 ppm for 60 240 minutes 150 ppm for 10 50 minutes and 400 ppm for 4 15 minutes When CO is detected and...

Page 5: ...22 hours by pressing the test button This end of life silence feature can only be used for a total of 30 days After 30 days the end of life signal cannot be silenced During this end of life silence p...

Page 6: ...nd make sure that they are both turned on to ensure successful connection NOTE Install the batteries correctly to turn on CO03D W To learn how to turn on different models of wireless interlinked alarm...

Page 7: ...NOTES 1 The alarm will enter the searching mode or the pairing mode for 60 seconds with the red LED flashing After 60 seconds repeat step 2 to connect the alarms If needed press the TEST HUSH button o...

Page 8: ...rm be tested during the weekly test Test a single CO alarm Test all interconnected CO alarms Action Press the TEST HUSH button Hold down theTEST HUSH button Indication The LCD will turn on and display...

Page 9: ...e appliance is in a room not normally used such as a boiler room the CO alarm should be placed just outside of this room so that the alarm can be heard more easily 1 Installing a CO Alarm in a Room wi...

Page 10: ...room with a fuel burning appliance Figure 1 In rooms with sloped ceilings the CO alarm should be located at the high side of the room 2 Installing the CO Alarm in a Bedroom or Room Without a Fuel Bur...

Page 11: ...y areas 2 Where there is the possibility of smoke or fumes under normal operating circumstances 3 In poorly ventilated kitchens garagesand furnace rooms Keep the CO alarms at least5 feet 1 5 m from po...

Page 12: ...rd the wall and the curved hole at the lower position 2 Mark 2 screw holes according to the holes on the mounting bracket then remove the bracket and drill the screw holes to a depth of 1 18 in 30 mm...

Page 13: ...sh 3 times sequentially every 1 5 seconds 3 long beeps every 1 5 seconds Dangeroussmoke concentration is detected by the initiating unit in the network Please find the initiating unit and take action...

Page 14: ...yellow LED indicator flashes 3 times every 60 seconds None Silence mode during the end of the cycle After 22 hours the unit will exit silence mode The green LED indicator flashes 3 times None Exiting...

Page 15: ...larm are triggered in the network at the same time the alarm signal of the smoke alarm will take priority over that of the CO alarm This alarm has a relay function that extends the wireless interconne...

Page 16: ...uated the area or has access to fresh air Do not re enter the house until it has been aired out and your alarm remains under normal condition If it is not possible to move outside stay close to an ope...

Page 17: ...detect CO that reaches the sensor CO may be present in other areas Doors or other obstructions may affect the rate at which CO reaches the CO alarm For this reason if bedroom doors are usually closed...

Page 18: ...ioning The wireless signal might be blocked or out of range The yellow LED flashesonce every 60 seconds with one beep The battery is low Replace the battery immediately The yellow LED flashestwice eve...

Page 19: ...equipment This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any int...

Reviews: