Page 17
Bolt Sequences
The ‘Bolt Sequences’ button allows the user to select which parameter(s) will run for a given bolt inside
each task. To assign a parameter to a bolt, select the bolt number (or multiple bolts if they will all have
the same parameter(s)) then tap the button to the right to access the parameter list. Tap the parameter
name you wish to choose to select that parameter for that bolt.
The ‘Number of Bolts’ is assigned in the ‘Setup’ screen on each task, reference the ‘Setup Screen’
section of this manual for more information.
Multiple bolts can be grouped together and all assigned parameters simultaneously, and they would
need to be selected and ungrouped to program separately again.
Each bolt can have up to 5 parameters assigned to run in sequence as well. A time delay between
parameters may be programmed in this screen should the application require it. When the bolt count is
50 or less, each bolt can be selected separately to assign it any of the 8 available parameters on that
task.
When using multiple parameters on a single bolt, only one trigger pull is required for the bolt, but must
be held until the entire sequence is completed. Releasing the trigger in the middle of the sequence will
result in a ‘sequence aborted’ error.
Should one step of a sequence fail during a rundown, the bolt will fail at that point and not proceed to
the next step of the sequence.