Page 118
160337-000 Rev D, 30 September, 2013
Xiotech—Proprietary
ISE User Guide
Monitoring
Table 38:
Sample: Show DataPac Console Print
Power Supply Detailed
Enter the
show powersupply
or
show ps
command in the CLI. The following information (Table 39) is
displayed for each power supply and a sample display for a single power supply is shown in Figure 85.
Firmware Version
:
100 (4202) Cache Generation: 1
Temperature
:
31 C (Warning: 50 C, Critical: 60 C)
--------------------------------------------------------------------------
======================================================================
Field
Comment
Status
Overall DataPac state, normal is
Operational
and other possible states:
Warning
,
Criti-
cal
,
and
Non-Operational
Detailed Status
Normally
None
. Abnormal states are detailed here
Redundancy Health
Functional, relative DataPac storage remaining
Serial Number
DataPac serial number
Model
Model number of DataPac
Part Number
DataPac part number
Firmware Version
DataPac firmware version
Type
DataPac classification as Performance, Balanced, or Capacity
Capacity
DataPac capacity stated in total Gigabytes (GB)
Position
Physical bay location in the chassis; see Figure 101 on page 140
Pool Identifier
Values appearing in parenthesis after the DataPac number and are
0
or
1
Temperature
DataPac temperature plus warning and critical temperature thresholds (see “Tempera-
ture Indicators” on page 116 for display details and SNMP trap information)
Field
Comment
Status
Overall power supply state, normally
Operational
, other possible states:
Warning
,
Critical
,
and
Non-Operational
Detailed Status
Shown in parentheses after Status; normal is
None
, abnormal states are detailed here
Serial Number
Serial number of the power supply
Model
Model of the power supply
Part Number
Part number of the power supply
Blower Status, Speed
Each power supply contains two blowers, all of which operate independently under sys-
tem control. Speeds are grouped into ten RPM ranges, from 1 (slowest) to 10 (fastest).
Position
Physical bay location in the chassis; see Figure 101 on page 140
Temperature
DataPac temperature plus warning and critical temperature thresholds (see “Temperature
Indicators” on page 116 for display details and SNMP trap information)
Summary of Contents for ISE-2 Series
Page 1: ......
Page 36: ...Page 28 160337 000 Rev D 30 September 2013 Xiotech Proprietary ISE User Guide Installation...
Page 44: ...Page 36 160337 000 Rev D 30 September 2013 Xiotech Proprietary ISE User Guide Management Tools...
Page 108: ...Page 100 160337 000 Rev D 30 September 2013 Xiotech Proprietary ISE User Guide ISE Management...
Page 132: ...Page 124 160337 000 Rev D 30 September 2013 Xiotech Proprietary ISE User Guide Monitoring...
Page 154: ...Page 146 160337 000 Rev D 30 September 2013 Xiotech Proprietary ISE User Guide Maintenance...
Page 158: ...Page 150 160337 000 Rev D 30 September 2013 Xiotech Proprietary ISE User Guide FRU Replacement...
Page 178: ......