background image

14

Technical support: [email protected]     EMEA/ROW: +44 (0) 1793 230 343

US/CAN/MEX: +1-518-289-1294     Toll Free Technical Support: +1-844-280-WYRE (9973)

INST

ALLA

TION REFERENCE LOG

14

Input

#

IR TX

Input

#

Ethernet

RS232

Sensor I/O

1

1

2

3

2

4

5

3

6

7

4

8

9

5

10

11

6

12

13

7

14

15

8

16

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

Cable #

20.     Installation Reference Log

Summary of Contents for Enado

Page 1: ...ction Manual WyreStorm EnadoTM User Interface Controller eNA 001 010 WyreStorm Enado Controller with 16x IR 4x RS232 8x Ethernet and 4x I O Sensors Thank you for choosing this WyreStorm product Please...

Page 2: ...an run on any client device that offers a compatible web interface making the controller ideal for both professional and residential control For further information on this product and other WyreStorm...

Page 3: ...32 control and Ethernet pass through please see our full HDBaseT or HDBT Lite range of matrices transmitters receivers and extender sets USB to 5V Cable Part Number CAB USB 5V Full remote access enabl...

Page 4: ...8 IR blaster IR TX LED power indicator lit when powered LED work indicator lit when working set by software LED warn indicator lit when warning set by software IR IN IR RX receiver input IR blaster I...

Page 5: ...the Y shape dual jack IR emitters supplied with the controller avoids having two IR emitters on the source device IR Link cables are used to connect the matrix TX to Enado The RS232 lead should be a c...

Page 6: ...example if the application requires an even balance of inputs and outputs for control within an 8x8 matrix distribution the user should connect 8 IR outputs from the Enado Controller to the IR RX port...

Page 7: ...R MATRIX AND EXPAND DISTRIBUTION Full control of connected sources and displays through the Enado central controller from any global location via the multi platform browser based Enado User Interface...

Page 8: ...is automatically generated from the data used in the Standard UI configuration with some Compact UI specific configuration options This allows quick and easy editing and creation of the different scre...

Page 9: ...display calculated from the display device 9 Room Zone Global controls present in every activity page per room zone 10 System Settings main access to system configuration and management NOTE See Enado...

Page 10: ...e updating process has completed and the live configuration UI s are accessible from a web browser ii Accessing the configuration UI guide To access the full Configuration UI guide Select Editor User...

Page 11: ...an IP address conflict if there are other devices with statically assigned addresses on the network Central devices should where possible have static addresses assigned or have static addresses assign...

Page 12: ...the manufacturer or parts possessing the same characteristics as the original parts Be aware unauthorised substitutes may result in fire electric shock or other hazards and will invalidate your warran...

Page 13: ...warrantor is not liable for incidental or consequential damage resulting from the use of this product or arising out of any breach of this warranty For example damages for lost time the cost of havin...

Page 14: ...X Input Ethernet RS232 Sensor I O 1 1 2 3 2 4 5 3 6 7 4 8 9 5 10 11 6 12 13 7 14 15 8 16 Cable Cable Cable Cable Cable Cable Cable Cable Cable Cable Cable Cable Cable Cable Cable Cable Cable Cable Cab...

Page 15: ...15 US CAN MEX 1 518 289 1294 Toll Free Technical Support 1 844 280 WYRE 9973 NOTES 15 21 Notes...

Page 16: ...A Office Unit 22 Ergo Business Park Swindon Wiltshire SN3 3JW UK Tel 44 0 1793 230 343 WyreStorm Technical Support US 1 844 280 WYRE 9973 UK 44 0 1793 230 343 Email support wyrestorm com WyreStorm Tec...

Reviews: