The Extender boom should be unfolded into the field po

-

sition. The Extender boom is equipped with over-center 

breakaways that are cushioned with poly springs. Rotate 

the Extender boom wings to the field position. As the wing is 

rotated, the poly springs will compress causing resistance. 

This is normal and expected. 

Flip the control valves on, engage the pump and allow water 

to flow through the boom. Disengage the pump when the 

boom is flushed. 

Install the nozzles and tip screens on the nozzle bodies. 

Push the tip in the cap, place the gasket on top of the tip, 

add the tip strainer. Turn the cap clockwise ¼ turn to lock 

the cap onto the nozzle body.

The Extender boom is divided into three sections (center  

nozzles and each Boom Buster nozzle). The LCS sprayer 

will usually be equipped with a handgun as well. The Hypro 

manual control has three valves that controls the Extender 

boom. An attached ball valve controls the handgun. 

Figure A7

Extender Boom

       Transport Position 

Field Position

Figure A8

Installing Spray Nozzles

Agitator >

Valve

< Handgun

   Valve

Boom >

Valves

< Pressure 

   Adjustment 

   Knob

Figure A9

LCS Control with Extender Boom

The LCS sprayer may also be equipped with an electric 

control valve that can be operated from the tractor cab. A 

variety of electric control systems are available. A typical 

system will include solenoid valves, a pressure adjustment 

valve and a control console. Refer to the operation instruc

-

tions that are included with the control system.   

Figure A10

Electric Control

Inspection & Setup

< Pressure

   Adjustment

   Valve

< Solenoid V

alves

<  Electric Console

Summary of Contents for LCS Sprayer

Page 1: ...Operator s Parts Manual LCS Sprayer Printed In The USA Specifications Design Subject To Change Without Notice 4 1 18 02 025R7 ...

Page 2: ...n to the LIMITED WARRANTY Polyethylene and fiberglass tanks These tanks are warranted for the storage and transport of water herbicide solutions on farm liquid fertilizer and liquid feed Such tanks should not be used for the storage of any bulk herbicide undiluted Any such use will render this warranty void In addition the Warrantor makes no warranty with regard to bulkhead tank fittings used in c...

Page 3: ...k Serial Number Trailer Serial Number Pump Model Wylie Invoice Number Owner s Name Address City State Zip Phone Email Dealer Owner s Signature Must be returned within 10 days to validate the warranty Type of Applicator Vegetable Cotton Wheat Pasture Other Owner Registration Or Register Online Go to www wyliesprayers com ...

Page 4: ... ...

Page 5: ...ockman Special Trailer Round Tank 27 Hypro 7560 Roller Pump and Plumbing 28 Hypro Manual Control and Plumbing 29 SCS 203HV Triple Electric Control 30 TIR 1999A Solenoid Valve 31 Ace 206 Centrifugal Pump and Plumbing 32 Extender Boom 33 8220 boom 34 Boom Buster Kit 35 Hose Gun Kit 36 Single Broadcast Nozzle Attachment 36 CDS John Blue Gear Pump 36 Hypro 7560 Pump 37 Hypro Manual Control 38 43 Gunje...

Page 6: ... damage SAFETYINSTRUCTIONS Indicates a type of safety sign where specific safety related instructions or procedures are described Before Use Do not operate sprayer until this manual has been read and understood Thoroughly read and understand all instructions before operating this sprayer If you have questions please contact Wylie Manufacturing 702 E 40th St Lubbock TX 79404 888 788 7753 You can al...

Page 7: ...ng lines Tighten all connections prior to starting engine or pressurizing line If any fluid is injected into the skin obtain medical treatment immediately to avoid gangrene Operator s Instructions Securely fasten seat belt if tractor is equipped with a ROPS When possible avoid operating the tractor near ditches embankments and holes Reduce speed when turning crossing slopes and on rough slick or m...

Page 8: ...4 Safety Decals Placement Safety Issues Decal V9055 Decal SW700 LCS Sprayers Decal SW701W ...

Page 9: ...livestock watering remote locations or fighting grass fires are just a few of the uses This manual explains where and how to make necessary adjustments to your sprayer for safe and proper operation Thoroughly read and understand the contents of this manual before operating your sprayer If you have questions or do not understand particular items contact your nearest Wylie Spray Center or call Wylie...

Page 10: ...aft Failure to do so could possibly cause serious injury or death Figure A1 Height Adjustable Hitch Figure A2 Pump With Drive Shaft Direct Coupled Pump If your sprayer is equipped with the direct coupled pump make sure that the chain is attached to the frame of the tractor to prevent rotation of the pump See Figure A2 Preparing Sprayer for Operation Add about 50 gallons of water to the spray tank ...

Page 11: ...out Figure A4 Off Control Valves On Control Valves Figure A5 Adjusting Pressure Relief Valve It may be necessary to partially close the agitator ball valve in order to set the proper pressure A fully open agitator valve may prevent sufficient fluid to be available for ad equate pressure Maximum pressure for the 7560 Hypro pump is 300 psi Maximum pressure for the CDS John Blue gear pump is 200 psi ...

Page 12: ...hree sections center nozzles and each Boom Buster nozzle The LCS sprayer will usually be equipped with a handgun as well The Hypro manual control has three valves that controls the Extender boom An attached ball valve controls the handgun Figure A7 Extender Boom Transport Position Field Position Figure A8 Installing Spray Nozzles Agitator Valve Handgun Valve Boom Valves Pressure Adjustment Knob Fi...

Page 13: ...ank Add the correct amount of chemical to the sprayer tank Read the instructions on the chemical container for details regarding the proper amount of chemical to add Assure the control valve is off before starting the pump Engage the pump and check that the agitator valve is open Let the pump run for a few minutes to thoroughly mix the solution Boom Buster Operation Move the sprayer to the area to...

Page 14: ... obstructions animals or people while spraying While the Extender boom is equipped with a breakaway to help protect the boom damage or injury can occur in a collision The LCS sprayers are designed to operate at 4 6 mph Care and common sense however must be used to determine the optimum speed for a particular spraying operation Fac tors such as rough surface conditions hillsides terraces and turns ...

Page 15: ...3 19 8 17 8 16 2 14 9 13 7 12 7 11 9 11 1 10 5 9 9 9 4 8 9 8 5 8 1 7 7 7 4 50 MESH 50 0 34 24 9 22 1 19 9 18 1 16 6 15 3 14 2 13 3 12 4 11 7 11 1 10 5 9 9 9 5 9 0 8 7 8 3 BLUE 60 0 37 27 2 24 2 21 8 19 8 18 2 16 8 15 6 14 5 13 6 12 8 12 1 11 5 10 9 10 4 9 9 9 5 9 1 20 0 28 21 0 18 7 16 8 15 3 14 0 12 9 12 0 11 2 10 5 9 9 9 3 8 8 8 4 8 0 7 6 7 3 7 0 30 0 35 25 7 22 8 20 6 18 7 17 1 15 8 14 7 13 7 1...

Page 16: ...hen close the Quick Fill valve before disconnecting the fill hose Open the pump valve before engaging the pump If the sprayer is equipped with an Extender Boom unfold the boom out into the field position Setting the Pump Refer to the enclosed manual for the CDS John Blue NGP6055 pump for instructions on setting the pump for the desired application rate Also included is a Slide Chart P N 115698 91 ...

Page 17: ...y to increase the pressure call Wylie Service for instructions To disengage the pump loosen the pressure release lever and gravity will return the drive wheel to the transport posi tion Retighten the pressure release lever Pressure Release Lever Hand Pump Pump Handle Figure B7 Hand Pump Tractor Hydraulic System Plug the hydraulic hoses into a tractor hydraulic circuit Extend the cylinder to engage...

Page 18: ...o be flushed with clean water to prevent pump damage Add 5 10 gallons of clean water to an empty spray tank Turn the pump on and apply this flush solution to a safe area Check the sprayer for any leaks or damaged parts Repair or replace as necessary Operation during cold weather may require protecting the sprayer from freeze damage See the next section for instructions End of Season Procedure Thor...

Page 19: ...Wylie Spray Center 7 Increase PTO speed 8 Increase hydraulic fluid pressure Controller gun or nozzles do not operate 1 Control valve handle not engaged 2 Malfunctioning controller 1 Rotate valve handle up to engage 2 Repair or replace control valve or contact Wylie Spray Center No output or insufficient pressure at spray tip s 1 Air leak in suction side of system 2 Problem with pump 3 Control valv...

Page 20: ...16 Hypro Pump Information Pump Information ...

Page 21: ...17 Pump Information Hypro Pump Operation Maintanence Con t ...

Page 22: ...18 Pump Information ...

Page 23: ...19 Pump Information ...

Page 24: ...20 Pump Information ...

Page 25: ...21 Pump Information ...

Page 26: ...22 Notes Notes ...

Reviews: