UV Purification Systems
24
Accessories
UV Monitoring System
A Wyckomar UV Monitor (available separately) measures true UV intensity at 254
nm, which is the effective germicidal wavelength for UV treatment of drinking wa-
ter. It continuously monitors lamp output inside the reaction chamber through a
sensor in the viewport, regardless of whether or not water is flowing through the
system. UV intensity is constantly displayed in real-time on the meter face on the
monitor device. If the UV intensity emitted by the lamp drops below the alarm
set-point (70% of new lamp UV output), the audible alarm will sound. An optional
solenoid valve may be connected to the monitor to stop the water flow.
The UV Monitor is available with volt-free contacts for remote signaling of opera-
tion, and also with 4-20mA output for remote operation logging (see Page 25).
Installation instructions are supplied with the UV Monitor.