17
Start-up
Preselect the speed of the abrasive belt according to
the speed table using the setting wheel.
Level
m/s
rpm
1
4.8
3000
2
6.5
3400
3
8.2
4600
4
9.8
5800
5
11.5
7000
6
13.2
8300
Never increase the belt speed adjusted
to the abrasive belt during operation!
Switching on/off
▸
Move the switch to the OFF position.
3
«0» is visible.
▸
To switch on the machine, press the switch and
slide it forward until it audibly engages.
3
«1» becomes visible.
▸
The lock is released by pressing the ON/OFF
switch.
3
The machine turns off.
Technical data
Art.
5706 110 X
Nominal voltage
230/240V,
50/60Hz
Power consumption
600 W
Power output
300 W
Band speed in No load
mode
13.2 m/s
Length of the abrasive belt
520 mm /
20 1/2“
Width of the abrasive belt
3-19mm /
1/8“-3/4“
Type of abrasive belt
Fleece and abra-
sive belts
Thickness of the abrasive belt
max. 4 mm
Sound pressure level
IEC 62841
82 dB(A),
K=3 dB(A)
Sound power level
93 dB(A),
K=3 dB(A)
Art.
5706 110 X
Vibration IEC 62841*
2.5 m/s
2
,
K=1.5 m/s
2
Weight without cable
2.2 kg
Protection class
/II
* The specified vibration emission values:
• Were measured using a standardised test method
and can be used to compare one electric tool
with another.
• Can be used for a rough assessment of the
exposure.
Operating conditions
Operating temperature
range
0 to +50°C
Relative humidity
95% at +10 °C
non-condensing
Operation
Machine protection
Starting current limitation
The electronically controlled soft start ensures a
smooth start of the machine. Due to the low starting
current of the machine, a 16 A fuse is sufficient.
Temperature-dependent overload
protection
To protect against overheating, the safety electronics
switch to cooling mode when a critical temperature
is reached. The machine then continues to run for
approx. 1300 min
-1
and the constant electronics
are deactivated. After a cooling time of approx. 10
to 20 seconds, the machine is ready for operation
again.
▸
Switch the machine off and on again to activate
the constant electronics. The temperature-depen-
dent overload protection reacts accordingly ear-
lier when the device is at operating temperature.
Low voltage protection / restart protection
3
The machine stops if the supply voltage briefly
fails (disconnected plug, unstable supply network,
etc.).
▸
After restoring the supply voltage, the machine
must be switched off and on.
3
The machine is ready for operation.
Summary of Contents for ESF 500-E Universal
Page 3: ...II 2 1 3 4 5 8 9 6 7 10 3 I...
Page 92: ...92 GR Adolf W rth GmbH Co KG 3 3 1...
Page 93: ...93 a b c d e f g h i j...
Page 94: ...94 k l m n o p a b c d e a...
Page 95: ...95 FI...
Page 98: ...98 3 3 3 3 90 1 mm 3 3 150 W rth FI...
Page 156: ...156 BG Adolf W rth GmbH Co KG 3 3 1...
Page 157: ...157 a b c d e f g h i j...
Page 158: ...158 k l m n o p a b c d e a...
Page 159: ...159 FI...
Page 162: ...162 3 3 150 W rth FI W rth 15 C 50 C 90 30 C 65 50 C...
Page 188: ...188 RU Adolf W rth GmbH Co KG 3 3 1...
Page 189: ...189 a b c d e f g h i j...
Page 190: ...190 k l m n o p a b c d e a...
Page 191: ...191 FI...
Page 194: ...194 3 3 150 W rth FI W rth...
Page 212: ...212...
Page 213: ...213...
Page 214: ...214...