13
30-10001669
TESTING AND OPERATION:
1. Slide the Sensor Block up next to the Rail End
Clamp with the wire spool. Make sure the wire
is in the proper target hole.
2. Set the switch on the electrical enclosure to
“
ON
”.
3.
Test the system by intentionally moving the
wire so that it touches the edge of the target
and activates the alert system
. Refer to the
Troubleshooting section if the alert system
does not activate.
4.
Slide the Sensor Block along the rail.
If the alert system is activated at any time,
the rail is out-of-tolerance.
Visually inspect
the rail for physical deformities or foreign ob-
jects. Also, rotate the target to the visual in-
spection hole and check which direction the
rail is out-of-tolerance. Mark the location of
the non-conformity on the rail.
5. You can determine that a rail is within toler-
ance once you have reached the other end of
the rail with the Sensor Block without
activating the alert system.