WURM FRIGOLINK ANI-1F3 Manual Download Page 9

ANI-1F3

 ANI-1F3_V2.0.0_PI_2021-04_EN

9

Subject to technical changes

FRIGOLINK

1.4.2 

Output circuit diagram

Fig. 4: ANI-1F3 output circuit diagram

Digital outputs (relays) K 1 - K 14

11 12 13 14

71 72 73 74

81 82 83 84

238 237 236 235 234 233 232 231

250 249 248 247 246 245 244 243 242 241

201 202 203 204 205 206 207 208 209 210

211 212 213 214 215 216 217 218 219 220

221 222 223 224 225 226 227 228 229 230

44 43 42 41

151 152 153 154 155 156 157 158 159 160

194 193 192 191

190 189 188 187 186 185 184 183 182 181

180 179 178 177 176 175 174 173 172 171

170 169 168 167 166 165 164 163 162 161

98 99

140 139 138 137 136 135 134 133 132 131

120 119 118 117 116 115 114 113 112 111

130 129 128 127 126 125 124 123 122 121

110 109 108 107 106 105 104 103 102 101

µC

RS 485

PE

11

14

F-BUS

LAN

71

F-BUS

74

C-BUS

C-BUS

C-BUS

81

84

250

Uout 5...1 / 0-10V

241

V 4...1 / each 60VA max.

238

231

K 5...9 / each 4(2)A@230V~

211

201

210

K 1...4 / each 4(2)A@230V~

220

K 10...14 / each 4(2)A@230V~

221

230

S16

194

S 15...11 / Sensor

190

191

181

S 10...6 / Sensor

180

171 170

S 5...1 / Sensor

161

Iin 1...5 / 4-20mA

160

151

Uin 2, 1 / 0-10V

44

41

0-10V

GND

0-10V

GND

24V=

4-20mA

207,209
211,213
215,217
219,221
223,225
227,229

208,210
212,214
216,218
220,222
224,226
228,230

202,205

203,206

231,233
235,237

232,234
236,238

241,243
245,247
249

242,244
246,248
250

201,204

44,42

43,41

152,154
156,158
160

151,153
155,157
159

Relay

K 3-14

Relay

K1,K2

Solid State

Relay V 1-4

0-10V

Analog Output

Uout 1-5

0-10V

Analog Input

Uin 1, 2

4-20mA

Analog Input

Iin 1-5

Digital Inputs

DI 1-20

230V~/50Hz

140
130

N 20...11 / neutral terminal

DI 10...1 / 230V~

120
110

131
121

111

101

DI 20...11 / 230V~

N 10...1 / neutral terminal

N

230V~

101-110
121-130

111-120
131-140

N

max. 20VA

ANIMUS    ANI-1F3

part of Frigolink

7C451061A

7A4512710

7B451061A

250

Uout 5...1 / 0-10V

241

V 4...1 / each 60VA max.

238

231

K 5...9 / each 4(2)A@230V~

211

201

210

K 1...4 / each 4(2)A@230V~

220

K 10...14 / each 4(2)A@230V~

221

230

0-10V

GND

207,209
211,213
215,217
219,221
223,225
227,229

208,210
212,214
216,218
220,222
224,226
228,230

202,205

203,206

231,233
235,237

232,234
236,238

241,243
245,247
249

242,244
246,248
250

Relay

K 3-14

Relay

K1,K2

Solid State

Relay V 1-4

0-10V

Analog Output

Uout 1-5

201,204

238 237 236 235 234 233 232 231

250 249 248 247 246 245 244 243 242 241

201 202 203 204 205 206 207 208 209 210

211 212 213 214 215 216 217 218 219 220

221 222 223 224 225 226 227 228 229 230

Terminal

Digital output

Contact arrange-
ment

Assignment

201

Changeover contact 

K 1 / 

4(2)A@230V~

COM

Alarm output prio 1 

(NC)

202

NC

203

NO

204

Changeover contact 

K 2/

4(2)A@230V~

COM

Alarm output prio 2 

(NC)

205

NC

206

NO

207

NO contact K 3 /

4(2)A@230V~

COM

MT compressor 1 

operation

208

NO

209

NO contact K 4 /

4(2)A@230V~

COM

MT compressor 2 

operation

210

NO

211

NO contact K 5 /

4(2)A@230V~

COM

MT compressor 3 

operation

212

NO

213

NO contact K 6 /

4(2)A@230V~

COM

LT compressor 1 

operation / enable

214

NO

215

NO contact K 7 /

4(2)A@230V~

COM

MP too low

216

NO

217

NO contact K 8 /

4(2)A@230V~

COM

HR valve operation

218

NO

219

NO contact K 9 /

4(2)A@230V~

COM

HR pump operation

220

NO

221

NO contact K 10/

4(2)A@230V~

COM

Valve PC CP 2

222

NO

223

NO contact K 11 /

4(2)A@230V~

COM

Desuperheater fan 

operation

224

NO

225

NO contact K 12 /

4(2)A@230V~

COM

Gas cooler bypass 

(bypassed)

226

NO

Summary of Contents for FRIGOLINK ANI-1F3

Page 1: ...compressor fault 3 step load shedding including Fastreturn Operating hours counter and cycle counter for each compressor Proactive oil return High pressure and medium pressure control Gas cooler fan c...

Page 2: ...S 16 8 1 4 2 Output circuit diagram 9 Digital outputs relays K 1 K 14 9 Digital outputs SSR V 1 V 4 10 Analogue outputs Uout 1 Uout 5 10 1 4 3 Communication circuit diagram 11 Communication 11 1 4 4...

Page 3: ...NG DANGER TO LIFE FROM ELECTRIC SHOCK AND OR FIRE Switch off the power to the entire plant when carrying out installation wiring or removal work Otherwise a mains voltage and or external voltage may s...

Page 4: ...r individual projects and are not described in detail in this document This document automatically ceases to be valid if a new technical description is issued Manufacturer Wurm GmbH Co KG Elektronisch...

Page 5: ...V Analog Input Uin 1 2 4 20mA Analog Input Iin 1 5 Digital Inputs DI 1 20 230V 50Hz 140 130 N 20 11 neutral terminal DI 10 1 230V 120 110 131 121 111 101 DI 20 11 230V N 10 1 neutral terminal N 230V 1...

Page 6: ...Digital Inputs DI 1 20 230V 50Hz 140 130 N 20 11 neutral terminal DI 10 1 230V 120 110 131 121 111 101 DI 20 11 230V N 10 1 neutral terminal N 230V 101 110 121 130 111 120 131 140 N max 20VA ANIMUS A...

Page 7: ...n fault 138 N 129 DI 19 230V Alarm input 1 NC 139 N 130 DI 20 230V Alarm input 2 NC 140 N Terminal Analogue input Potential Assignment 41 Uin 1 GND Not available 42 0 10V 43 Uin 2 GND Not available 44...

Page 8: ...perature LT compres sor 167 168 S 4 TRK Outside temperature 169 170 S 5 DGF Gas cooler outlet temperature T gc 1 171 172 S 6 DGF Gas cooler outlet temperature T gc 2 173 174 S 7 DGF Outlet temperatur...

Page 9: ...DI 1 20 230V 50Hz 140 130 N 20 11 neutral terminal DI 10 1 230V 120 110 131 121 111 101 DI 20 11 230V N 10 1 neutral terminal N 230V 101 110 121 130 111 120 131 140 N max 20VA ANIMUS ANI 1F3 part of F...

Page 10: ...A 230V NO HG bypass 232 COM 233 Semiconductor V 2 4 60VA 230V NO Post injection PWM 234 COM 235 Semiconductor V 3 4 60VA 230V NO HP evaporator EEV PWM 236 COM 237 Semiconductor V 4 4 60VA 230V NO Valv...

Page 11: ...4 2 A 230V 211 201 210 K 1 4 each 4 2 A 230V 220 K 10 14 each 4 2 A 230V 221 230 S16 194 S 15 11 Sensor 190 191 181 S 10 6 Sensor 180 171 170 S 5 1 Sensor 161 Iin 1 5 4 20mA 160 151 Uin 2 1 0 10V 44 4...

Page 12: ...R valve closed 21 26 DI 5 HR pump fault 21 27 DI 6 Heat pump blocking 21 28 DI 7 LT compressor 2 operating feedback 21 29 DI 8 LT compressor 2 fault Terminal Output Assignment 18 19 Aout 0 10V HR air...

Page 13: ...t available Terminal Input Assignment 36 39 DI 1 Flow monitor 37 39 DI 2 Frost protection 38 39 DI 3 Air conditioning request Terminal Output Assignment 41 42 Aout 1 0 10V HP evaporator EEV 42 43 Aout...

Page 14: ...2 Not available 38 39 DI 3 Not available Terminal Output Assignment 41 42 Aout 1 0 10V GC bypass 42 43 Aout 2 0 10V IHE valve 18 19 K 1 IHE oil valve 16 17 K 2 Not available 14 15 K 3 Not available T...

Page 15: ...off Top hat rail installation 1 There are 2 fastening safety catches located on the back of the module A Press both fastening safety catches a downward until they engage with a click 2 There are 4 ret...

Page 16: ...x DGF TRK C BUS communication 3 wire CAN bus interface shielded galvanically isolated screw ter minals 2 5mm2 and RJ45 socket for communicating with system devices F BUS communication 3 wire CAN bus...