FKE003

 

 
 

Product information 

 

FKE003_V2.2_PI_2018-01_EN 

Subject to technical changes 

Page 1 of 8 

Front view 

Field module with semiconductor relay for EEV 
for installation in refrigeration units for cold locations 

 

 

 

 

Features 

  Operation of electronic expansion valves pulsed by integrated electronic relay (valve 

controller 230V~) or ATV230 (valve actuation 230V~/=) 

  Control of one evaporator per module 

  Integrated temperature display 

  Tool-free front installation 

  Fixed input/output allocation for sensors, control inputs and relays 

  Emergency program in case of CAN bus errors 

  External power supply over TR9-9-4 

  Secure connection through prefabricated accessories (ZCB) 

  Front panel with seal frame for increased splash protection 

  Connection to master module via Wurm CAN field bus (F-BUS) 

 

Summary of Contents for FKE003

Page 1: ...ctronic relay valve controller 230V or ATV230 valve actuation 230V Control of one evaporator per module Integrated temperature display Tool free front installation Fixed input output allocation for se...

Page 2: ...ric shock and or fire Switch off the power to the entire plant when installing wiring or removing Otherwise a mains voltage and or external voltage may still be present even if the control voltage is...

Page 3: ...rol elements 5 4 Device operation 5 4 1 Activating the advanced level 5 4 2 Selecting parameters 5 4 3 Set parameter 6 4 4 Set module number 6 4 5 Block keys against unauthorised operation 6 5 Paramet...

Page 4: ...for the FKE003 Cables Application ZCB C TR 0 6 Controller transformer 0 6m ZCB C TR 2 0 Controller transformer 2 0m ZCB C REL2M 5P Controller load 5 pin ZCB C DI 2 0 Controller digital inputs 2 0m ZC...

Page 5: ...Advanced level will flash for as long as the level is released P P 5s 2 To return to the advanced level press the P key again for 5 seconds If no key is pressed within 2 minutes the display automatic...

Page 6: ...ed within 2 minutes the display automatically returns to the standard level and parameter change is disabled The jump back is always made to the temperature display 4 4 Set module number For easier se...

Page 7: ...ure of suction gas sensor S4 P05 Actual value 4 20mA 0 25 5 Current on 4 20mA input resolution 0 25 5mA P06 Actual value 0 10V output 0 100 Triggering of the 0 10V output resolution 0 100 P07 Sensor t...

Page 8: ...d connection supply air return air defrost limit 1 x TRK EEV 7ST suction gas Analogue input 4 20mA output voltage 18V max 22mA Digital inputs 3 x potential free contact 1 x cold location off 1 x 2nd s...

Reviews: