FLEXCOMM 2000
(P-2000/C-2000/RT-2000)
OPERATOR’S MANUAL
2.
Basic Operations
A. Front Panel & Controls
DISPLAY - The P-2000 has a color LCD display. It provides the visual feedback for the system. Exactly
what is displayed depends on the current operating mode of the P-2000. During normal operation, the top
area shows information for FM #1 and the bottom line shows information for FM #2.
The keypad and cursor/value rotary knobs perform functions on the transceiver that is highlighted in blue.
The blue highlight also indicates which transceiver has been selected for transmitting when the system is
operating in SINGLE MIC MODE. This is the mode where there is only one audio panel position being
shared between the two transceivers.
FM #1 SELECT
– This button selects FM #1 as
the active transceiver. This is depicted on the
display by the FM1 area turning a bright blue
color. The keypad and cursor/value knobs will
now operate exclusively on the FM1 transceiver.
FM #2 SELECT
- This button selects FM #2 as
the active transceiver. This is depicted on the
display by the FM2 area turning a bright blue
color. The keypad and cursor/value knobs will
now operate exclusively on the FM2 transceiver.
FM #1 TRANSFER –
The button will transfer
(Flip-flop) the active and standby channels for
FM1.
FM #2 TRANSFER –
This button will transfer
(Flip-flop) the active and standby channels for
FM2.
FM #1 VOLUME
KNOB
– This rotary switch is
used to control the volume of FM #1. Pressing
the button will perform a “Test” of the audio
system by allowing audio from that transceiver
to be sent to the headset. This is used to vary
volume levels of that transceiver.
FM #2 VOLUME
KNOB
– This rotary switch is
used to control the volume of FM #2. Pressing
the button will perform a “Test” of the audio
system by allowing audio from that transceiver
to be sent to the headset. This is used to vary
volume levels of that transceiver.
CURSOR KNOB
– This rotary switch is used to
move the cursor around the display.
VALUE KNOB
– This rotary knob is used to
modify values at the cursor position.
ENTER/PWR button
– Pushing the VALUE
KNOB (Small rotary knob) button performs
“Enter” and power on/off operations.
DATA PORT
– This connector is used to
transfer data between the P-2000 and
Encryption Key loaders or for loading preset
channel information via the Motorola CPS
software (PC based).
FM #1 Select
FM #2 Select
FM #1 Volume
FM #2 Volume
Data Port
Cursor Knob
Keypad
FM #1 Transfer
FM #2 Transfer
Value/Enter/Pwr
Knob
Page 8 of 40
Publication No. 150-049105
Operator’s Manual
Rev. D
Oct 2007
These commodities, technology or software are controlled in accordance with the United States Export Administration Regulations. When exporting,
diversion contrary to U.S. law is prohibited.