background image

OPERATING MANUAL

ba75944e02 10/2014

Oxi 3310 IDS (Oxi 3315)

DIGITAL METER FOR DIGITAL IDS-D.O. SENSORS 

USB output

25.0

7.92

°C

01.09.2011

08:37

O

2

mg/l

Info

[Sal]

3310 IDS

Summary of Contents for Oxi 3310 IDS

Page 1: ...OPERATING MANUAL ba75944e02 10 2014 Oxi 3310 IDS Oxi 3315 DIGITAL METER FOR DIGITAL IDS D O SENSORS USB output 25 0 7 92 C 01 09 2011 08 37 O2 mg l Info Sal 3310 IDS...

Page 2: ...ight 2014 WTW GmbH Reproduction in whole or even in part is prohibited without the express written permission of WTW GmbH Weilheim Printed in Germany The latest version of the present operating manual...

Page 3: ...1 2 2 2 Requirements for safe operation 11 2 2 3 Unauthorized use 11 3 Commissioning 12 3 1 Scope of delivery 12 3 2 Power supply 12 3 3 Initial commissioning 12 3 3 1 Inserting the batteries 13 4 Ope...

Page 4: ...sensors menu for measurement and calibration settings 33 6 2 Sensor independent settings 34 6 2 1 System 34 6 2 2 Data storage 35 6 2 3 Automatic Stability control 35 6 2 4 Automatic switch off funct...

Page 5: ...atteries 47 9 2 Cleaning 48 9 3 Packing 48 9 4 Disposal 48 10 What to do if 49 10 1 Dissolved oxygen 49 10 2 General information 49 11 Technical data 51 11 1 Measuring ranges resolution accuracy 51 11...

Page 6: ...Contents Oxi 3310 IDS Oxi 3315 6 ba75944e02 10 2014...

Page 7: ...for all applications The Oxi 3310 IDS Oxi 3315 supports you in your work with the following func tions Automatic sensor recognition Electronic access control Data transmission via the USB interface U...

Page 8: ...the last 10 calibrations The calibration data are updated in the IDS sensor after each calibration pro cedure A message is displayed while the data are being updated in the sensor 1 2 2 Automatic sen...

Page 9: ...atic sensor recognition a meter that supports the automatic sensor recognition e g Oxi 3310 IDS Oxi 3315 and a digital IDS sensor are required In digital IDS sensors sensor data are stored that clearl...

Page 10: ...goods might be damaged if the actions mentioned are not taken 2 1 2 Safety signs on the meter Note all labels information signs and safety symbols on the meter and in the battery compartment A warning...

Page 11: ...for safe operation The meter may only be operated according to the authorized use specified above The meter may only be supplied with power by the energy sources mentioned in this operating manual The...

Page 12: ...ftware MultiLab Importer 3 2 Power supply The Oxi 3310 IDS Oxi 3315 is supplied with power in the following ways Battery operation 4 batteries 1 5 V Mignon type AA USB operation via a connected USB B...

Page 13: ...tly The signs on the batteries must correspond to the signs in the battery compartment You can operate the meter either with normal batteries or with rechargeable batteries Ni MH In order to charge th...

Page 14: ...ff Switches the meter on or off M Selects the measured parameter Quits the settings CAL CAL_ Calls up the calibration procedure Displays the calibration data STO STO_ Saves a measured value manually O...

Page 15: ...libration evaluation calibration interval 5 Measured temperature with unit 6 Status information meter 7 Softkeys and date time AR Stability control AutoRead is active HOLD Measured value is frozen AR...

Page 16: ...F1 Info softkey 1 Digital sensors Oxygen 2 USB B device interface 3 Service interface CAUTION Only connect sensors to the meter that cannot return any volt ages or currents that are not allowed SELV a...

Page 17: ...f The meter performs a self test 2 Connect the sensor The meter is ready to measure 1 Switch the printer off with On Off O2 mg l 7 92 25 0 C 01 02 2014 08 00 FDO 925 14010001 More Cap name SC FDO 925...

Page 18: ...ngs and dialogs in procedures contain further subelements The selection is made with the keys The current selection is dis played with a frame Submenus The name of the submenu is displayed at the uppe...

Page 19: ...carried out by confirming with ENTER Example Display the Calibration record function Messages Information is marked by the i symbol It cannot be selected Example General Interface Clock function Servi...

Page 20: ...Storage config menu The instrument is in the setting mode 3 Select the System submenu with The current selection is displayed with a frame 4 Open the System submenu with ENTER Calibration FDO Check Sa...

Page 21: ...etting with ENTER The meter switches to the measuring mode The selected language is active General Interface Clock function Service information Reset System 01 02 2014 08 00 Back Language Deutsch Audi...

Page 22: ...als Setting the date time and date format The date format can be switched from the display of day month year dd mm yy to the display of month day year mm dd yy or mm dd yy The date and time are reset...

Page 23: ...ith and ENTER The time is set 7 If necessary set the Date and Date format The setting is made similarly to that of the time 8 To make further settings switch to the next higher menu level with Back F1...

Page 24: ...concentration of solutions with a salt content of more than 1 g l a salinity correction is required For this you have to measure and input 1 Connect the D O sensor to the meter The D O measuring scree...

Page 25: ...n and measurement settings see section 6 1 1 SETTINGS FOR D O SENSORS MENU FOR MEASUREMENT AND CALIBRATION SETTINGS page 33 1 Freeze the measured value with AR The HOLD status indicator is displayed T...

Page 26: ...the FDO 925 D O sensor should be cleaned or calibrated 5 2 2 When should you check the sensor Checking can be useful in the following cases When the check interval has expired the check status indicat...

Page 27: ...n the check and storage beaker must be moist not wet Leave the sensor in the check and storage beaker long enough so it can adapt to the ambient temperature 3 Start the FDO check procedure in the meas...

Page 28: ...within the specified validity scope No cleaning or user calibration is required 5 3 Calibration 5 3 1 Why calibrate D O sensors age This changes the slope of the D O sensor Calibration deter mines th...

Page 29: ...O sensor to the meter 2 Place the FDO 925 D O sensor in the check and storage beaker FDO Check The sponge in the check and storage beaker must be moist not wet Leave the sensor in the check and storag...

Page 30: ...the air calibration vessel 1 Connect the D O sensor to the meter 2 Immerse the D O sensor in the reference solution 3 Start the calibration with CAL 4 Start the measurement with ENTER The measured val...

Page 31: ...e displayed concentration value to the nominal value value of the comparison mea surement Subsequently accept the correction multiplier with ENTER The meter switches to the measured value display The...

Page 32: ...n evaluation Calibration record USB output Display Calibration record Relative slope S 0 94 1 06 S 0 92 0 94 or S 1 06 1 08 S 0 90 0 92 or S 1 08 1 10 Error Error S 0 90 or S 1 10 Error elimination se...

Page 33: ...ay Displays the last calibration records max 10 Calibration Calibration data storage Output to RS232 USB Outputs the calibration data memory to the interface Calibration Calibration interval 1 180 999...

Page 34: ...signal filter is char acterized by the response time t90 This is the time after which 90 of a signal change is displayed Reset Resets all sensor settings to the delivery condition see section 6 3 1 R...

Page 35: ...see section 6 2 3 AUTOMATIC STABILITY CONTROL page 35 System Interface Baud rate 1200 2400 4800 9600 19200 Baud rate of the USB Device interface System Interface Out put format ASCII CSV Output format...

Page 36: ...pressed for an adjustable period The automatic switchoff function is not active if a USB B cable is connected if the Automatic data storage function is active or with automatic data trans mission 6 2...

Page 37: ...sured parameter in the measured value display and press the ENTER key 6 3 2 Resetting the system settings The following system settings can be reset to the default condition The calibration data are r...

Page 38: ...tings Oxi 3310 IDS Oxi 3315 38 ba75944e02 10 2014 The system settings are reset in the menu Storage config System Reset To open the Storage config menu press the ENTER_ key in the measured value displ...

Page 39: ...time output to the interface If the memory is full When all memory locations are occupied it is not possible to continue storing Then you can e g store the data from the memory to a PC see section 7...

Page 40: ...3 Graphical display of the memory usage ID number 1 Interval 30 s Duration 180 min continue 0d03h00min 0 1d17h33min Automatic data storage 1 2 3 01 02 2014 08 00 Back Menu item Possible setting Expla...

Page 41: ...follows to switch off the automatic data storage function before the adjusted storage duration has expired 1 Remaining storage duration 2 Graphical display of the storage duration If the automatic da...

Page 42: ...the RCL or RCL_ key Settings The settings are explained here using the manual data memory as an example The same settings and functions are available for the automatic data memory Menu item Setting f...

Page 43: ...measurement data memory see section 7 3 1 EDITING THE MEASUREMENT DATA MEMORY page 42 Manual data storage 3 of 64 01 02 2014 07 43 33 ID number 1 FDO 925 14010001 SC FDO 925 11200001 Ox 7 88 mg l 24 8...

Page 44: ...AR appears with the measured value if the AutoRead crite rion was met while storing stable measured value Otherwise the AR dis play is missing Calibration evaluation 4 levels or no evaluation 7 3 4 St...

Page 45: ...r installation of the USB driver PC with at least one free USB connection and CD ROM drive Windows 2000 Windows XP Windows Vista or Windows 7 1 Output the current measurement data to the USB B interfa...

Page 46: ...ou can set the transmission interval Simultaneously with every automatic data storage process see section 7 2 AUTOMATIC DATA STORAGE AT INTER VALS page 40 Stored mea sured values Manual Displayed data...

Page 47: ...nance 1 Screws 2 Battery compartment 1 Unscrew the two screws 1 on the underside of the meter 2 Open the battery compartment 1 on the underside of the meter 3 Remove the batteries from the battery com...

Page 48: ...e contact your supplier 4 Place four batteries type Mignon AA in the battery compartment 5 Close the battery compartment 2 and tighten the screws 1 6 Set the date and time see section 4 4 5 EXAMPLE 2...

Page 49: ...ured value outside the measuring range Use a suitable IDS D O sensor Cause Remedy Sensor contaminated Clean the sensor Measured temperature value outside the operating conditions display of OFL UFL in...

Page 50: ...ter or IDS sensor Cause Remedy E g a question by the service department Switch on the meter Open the menu ENTER_ Stor age config System Service infor mation The instrument data are displayed or Connec...

Page 51: ...i 3310 IDS Oxi 3315 Approx 0 4 kg Mechanical structure Type of protection IP 67 Electrical safety Protective class III Test certificates CE Ambient conditions Storage 25 C 65 C Operation 5 C 55 C Admi...

Page 52: ...e02 10 2014 Cable length Max 3 m Guidelines and norms used EMC EC directive 2004 108 EC EN 61326 1 EN 61000 3 2 EN 61000 3 3 FCC Class A Meter safety EC directive 2006 95 EC EN 61010 1 UL 61010 1 CAN...

Page 53: ...E VERSION IS IN THE METER OR IDS SENSOR PAGE 50 1 Install the downloaded firmware update on a PC An update folder is created in the Windows start menu If an update folder already exists for the meter...

Page 54: ...R IDS SENSOR PAGE 50 1 Install the downloaded firmware update on a PC An update folder is created in the Windows start menu If an update folder already exists for the sensor or sensor type the new dat...

Page 55: ...er AutoRange Name of the automatic selection of the measuring range Adjusting To manipulate a measuring system so that the relevant value e g the displayed value differs as little as possible from the...

Page 56: ...measured value stability Standard solution The standard solution is a solution where the measured value is known by definition It is used to calibrate a measuring system Temperature function Name of a...

Page 57: ...37 Display 15 F FDO Check 26 Firmware update 53 I Initial commissioning 12 Initialize 37 K Keys 14 M Measured value display 18 Measurement data memory Edit 42 Erase 42 Storage locations 44 Measuremen...

Page 58: ...Index Oxi 3310 IDS Oxi 3315 58 ba75944e02 10 2014...

Page 59: ......

Page 60: ...water needs Developing new technologies that will improve the way water is used conserved and re used in the future is central to our work We move treat analyze and return water to the environment and...