3-8
MT5634 Modem; AT Command Set
Command: &T
n
Loopback Test (V.54 Test) Commands
Values:
n
= 0, 1, 3, 6
Default:
None
Description:
The modem can perform selected test and diagnostic functions. A
test can be run only when the modem is operating in non-error-
correction mode (normal or direct mode). For tests 3 and 6, a
connection between the two modems must be established. To
terminate a test in progress, the escape sequence (
+++AT
) must
be entered.
&T0 Stops any test in progress.
&T1 Starts a local analog loopback, V.54 Loop 3, test. If a
connection exists when this command is issued, the
modem hangs up. When the test starts, a
CONNECT
message is displayed.
&T3 Starts local digital loopback, V.54 Loop 2, test. If no
connection exists,
ERROR
is returned.
&T6 Initiates a remote digital loopback, V.54 Loop 2, test
without self-test. If no connection exists,
ERROR
is returned.
Command: &V
Display Current Settings
Values:
N/A
Description:
Displays the active modem settings.
Command: &W
n
Store Current Configuration
Values:
n
= 0 or 1
Default:
1
Description:
&W0 Stores current modem settings in non-volatile memory
and causes them to be loaded at power-on or following
the
ATZ
command instead of the factory defaults.
See
&F
command.
&W1 Clears user default settings from non-volatile memory
and causes the factory defaults to be loaded at power-on
or following the
ATZ
command.
Command: &Z
y
=
x
Store Dialing Command
Values:
y
= 0–2 (0–1SMI-Parallel {internal})
x
= Dialing command
Default:
None
Description:
Stores dialing command
x
in memory location
y
. Dial the stored
number using the command
ATDS=
y
. See Also the
#CBS
command, a callback security command.