1``\YSQdY_^5hQ]`\U
$&
=_TYVYUT*(!% !
DUSX^Ydb_^D" % GU\T3_^db_\
$VVLJQ6FKHGXOH
Assign Schedule #5 to release and eject the part:
SCHEDULE=5
VALVE=0
;Turn off the clamp and gun
before the clamp is energized.
SQUEEZE DELAY=0
;N/A
SQUEEZE=40
;Give the clamp and electrodes
time to open before ejection.
UPSLOPE=0 ;N/A
WELD CYC=0
;N/A
WELD CUR=65%
;N/A
COOL=0 ;N/A
IMPULSES=1
;N/A
DOWNSLOPE CYC=0 ;N/A
SLOPE END CUR=20
;N/A
QUENCH CYC=0
;N/A
TEMPER CYC=0
;N/A
TEMPER CUR=0
;N/A
HOLD CYC=10
;N/A
WELD COMPLETE=30 ;Energize the ejector for a half-
second to eject the part. Use the
WCOMP output.
SUCCESSIVE SCH=0 ;N/A
CHAIN SCH=0
;NA
OFF CYC=0
;Off Single turns off all valves.
This completes the operation.