5.
Assign Schedule #2 to make the first spot weld:
SCHEDULE=2
VALVE=3
;The clamp is still on (SV1) add
SV2, and energize the gun valve
(SV1+SV2=3).
SQUEEZE DELAY=0
;N/A
SQUEEZE=40
;Give the electrodes time to close
and build pressure, the clamp is
still energized.
UPSLOPE=0 ;N/A
WELD CYC=8
;Weld time
WELD CUR=65%
;Pass 65% available current
COOL=0 ;N/A
IMPULSES=1 ;N/A
DOWNSLOPE CYC=0 ;N/A
SLOPE END CUR=20
;N/A
QUENCH CYC=0
;N/A
TEMPER CYC=0
;N/A
TEMPER CUR=0
;N/A
HOLD CYC=10
;N/A
WELD COMPLETE=0
;N/A
SUCCESSIVE SCH=3 ;Turn both valves off and wait for
another initiation. On re-initiation,
go to Schedule #3.
CHAIN SCH=0
;N/A (The sequence jumped to
Schedule #3.)
OFF CYC=0
;N/A
Summary of Contents for Technitron T2050