Usage and installation FAQ 
 

- What are the most obvious advantages of a ESWH? 

 

Can be installed individually or combined with a traditional system; 

 

Withstand pressure; 

 

Can operate with occasional tube breakages and these can be replaced easily; 

 

Works well in low-irradiance day with an electric booster 

- How to avoid cold water and hot water mixing? 

 

If the outflow rate is limited within 8L/min, this mixing can be avoided. 

- How to clean lime off heat pipes if they have been used for a long time? 

 

Carefully remove collector tubes, screw loose the heat pipe, clean the top end with 

chemical decontaminant. 

- Why does hot water flow intermittently some times? 

 

When the outflow rate is greater than the inflow, the relief valve on the top of tank will open 

and suck air in; the water level inside the tank will then be temporarily lower than the outlet 
connection, so hot water flow will stop. 

 

It is recommended that more than two showers or hot taps shall not be used at the same 

time. 

- Where to install pressure-reducing valve and safety valve? 

 

The pressure-reducing valve can be installed outside near the cold water connection on 

the bottom of the storage tank. But the safety valve shall be installed indoors. 

- What are the requirements for the piping and connections? 

 

Choose good aluminium and plastic compounds with heat-resistance over 90

°

C. 

 

And ask your local professionals to install your solar water heater. 
 

 
 

 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

Summary of Contents for JR-138

Page 1: ...iple of Operation 3 Assembly Instructions 3 Reflector Assembly 3 Frame Assembly 3 Connecting frame and reflector 4 Storage tank assembly 4 Unit Mounting Instructions 4 Mounting on roof ridge 4 Mountin...

Page 2: ...diance days The ESWH is available in several sizes depending on your hot water requirements Fig 1 Structure of ESWH 1 Insulation polyurethane foam 2 Inner cylinder AISI 316L 3 Outer shell galvanized s...

Page 3: ...f ESWH heater can be chosen between 30 or 45 Reflector Assembly 1 Place the module type reflectors side by side 2 Position the base bracket with larger parallel slots at the bottom Overlap the holes w...

Page 4: ...ent into place NOTE Leave the nuts loose as some alignment adjustment may be necessary after fitting tubes Unit Mounting Instructions Mounting on the roof ridge The assembled unit should be placed on...

Page 5: ...ils 3 Attach system securely to the roof either by 6 mm steel wires or if ground mounted the frame fastened to metal attachment points not supplied encased in cement blocks dimensions of each block 10...

Page 6: ...of the heat pipe into the aluminium fin already in the evacuated tube leaving enough of the heat pipe exposed to allow insertion of the heat pipe into the tank and for fastening of the threaded brass...

Page 7: ...es are covered the heat pipes can get hot enough to cause a burn injury and damage to the heat pipes will occur if the hot end of the pipe contacts cold water Only uncover the glass tubes once the tan...

Page 8: ...able temperature before showering or bathing 2 JB series solar water heater withstands pressure 0 5 kgf cm 3 The evacuated tubes resist temperatures as low as 70 when the tank is empty Under these con...

Page 9: ...y does hot water flow intermittently some times When the outflow rate is greater than the inflow the relief valve on the top of tank will open and suck air in the water level inside the tank will then...

Page 10: ...10 Trouble Shooting...

Reviews: