7. Slide the black rubber wind- blocking seals up the tube until the lip on the seal is flush with the 

tank. 
8. Insert all tubes to achieve alignment of the tank and the frame before fastening the frame nuts 

and bolts. 
9. Once fully assembled tighten all nuts and bolts. 

 

      

 

 

 

Precautions: 

1. Do not assemble in the sun unless the glass tubes are covered, the heat pipes can get hot 

enough to cause a burn injury, and damage to the heat pipes will occur if the hot end of the pipe 
contacts cold water. Only uncover the glass tubes once the tank is filled with water. 

2. Do not bend, distort or crush the copper heat pipe. 
3. Do not allow the copper joint of heat pipe to impact on the evacuated tubes during installation 

4. Do not untwist the copper joint of the heat pipe; it was sealed in the factory, and allowing the 
liquid inside to escape will render the heat pipe useless. 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 

Summary of Contents for JR-138

Page 1: ...iple of Operation 3 Assembly Instructions 3 Reflector Assembly 3 Frame Assembly 3 Connecting frame and reflector 4 Storage tank assembly 4 Unit Mounting Instructions 4 Mounting on roof ridge 4 Mountin...

Page 2: ...diance days The ESWH is available in several sizes depending on your hot water requirements Fig 1 Structure of ESWH 1 Insulation polyurethane foam 2 Inner cylinder AISI 316L 3 Outer shell galvanized s...

Page 3: ...f ESWH heater can be chosen between 30 or 45 Reflector Assembly 1 Place the module type reflectors side by side 2 Position the base bracket with larger parallel slots at the bottom Overlap the holes w...

Page 4: ...ent into place NOTE Leave the nuts loose as some alignment adjustment may be necessary after fitting tubes Unit Mounting Instructions Mounting on the roof ridge The assembled unit should be placed on...

Page 5: ...ils 3 Attach system securely to the roof either by 6 mm steel wires or if ground mounted the frame fastened to metal attachment points not supplied encased in cement blocks dimensions of each block 10...

Page 6: ...of the heat pipe into the aluminium fin already in the evacuated tube leaving enough of the heat pipe exposed to allow insertion of the heat pipe into the tank and for fastening of the threaded brass...

Page 7: ...es are covered the heat pipes can get hot enough to cause a burn injury and damage to the heat pipes will occur if the hot end of the pipe contacts cold water Only uncover the glass tubes once the tan...

Page 8: ...able temperature before showering or bathing 2 JB series solar water heater withstands pressure 0 5 kgf cm 3 The evacuated tubes resist temperatures as low as 70 when the tank is empty Under these con...

Page 9: ...y does hot water flow intermittently some times When the outflow rate is greater than the inflow the relief valve on the top of tank will open and suck air in the water level inside the tank will then...

Page 10: ...10 Trouble Shooting...