Out-1 Name Vu-Meter
-> Vu-Meter = RMS Cmp
When the Peak Limiter's activity is selected, the LED meters will show, from top down, the activity of the Peak
Limiter on the output
Out-1 Name Vu-Meter
-> Vu-Meter = Limiter Act
Name page
– from this screen it is possible to assign a 6 character name to the Output Channel.
The following is an example screen for a “Name” page labeled “Low” for Output Channel 1:
Out-1 Low Name
Name = Low
To Edit press ENTER on the Name Page and the entering arrow will appear as in the example below:
Out-1 Low Name
-> Name = Low
The first letter position will be blinking.
Select the Character position from the 6 available by rotating the “NAV/PM1” encoder, then by using the “PM2” or
'PM3” encoder it is possible to select the desired character.
Once you are happy with your name selection, press “ENTER” to confirm the edited Name. The new name will be
stored. The following example shows “Sub” replacing our previous name of “Low”:
Out-1 Sub Name
Name = Sub
Source page
– from this page it is possible to assign anyone of the Inputs to any Output Channel with the desired
percentage of level, as in 4 channel mixer:
1.
Input A with x% or Muted
2.
Input B with y% or Muted
3.
Input C with k% or Muted
4.
Input D with z% or Muted
In order to select the Inputs to assign to the the output and its percentage, need to access the Source Page Sub
Menu pressing ENTER, then selecting with the PM1 encoder the Input to assign or Mute and with the PM2 and
PM3 encoders, if to MUTE that input (PM2) or to assign with the desired percentage from -30dBu (min level) up to
00dBu (max) with the PM3.
\