background image

 

67 

 

Collective Reading 

 

 

 

Start Setup   

 

 

 

 

 

End Setup

 

 

 

,ZZ,

         

,ZZ,

 

Collective Reading Settings: 

It is possible to not output data unless the specified number of codes is read.  That means that the scanner does 
not read codes other than the specified number.  Use this setting to read a group of labels all at once. 

Multiple Label 
Read 

multiple label = 1 

default 

,D01,

 

multiple label = 2 

 

,D02,

 

multiple label = 3 

 

,D03,

 

multiple label = 4 

 

,D04,

 

multiple label = 5 

 

,D05,

 

multiple label = 6 

 

,D06,

 

multiple label = 7 

 

,D07,

 

multiple label = 8 

 

,D08,

 

multiple label = 9 

 

,D09,

 

multiple label = 10 

 

,D0A,

 

 

Multiple Label 
Read 
(right and left) 

left to right 

default 

,D0N,

 

right to left 

 

,D0O,

 

 

Multiple Label Read 
(top and bottom) 

top to bottom 

default 

,D0P,

 

bottom to top 

 

,D0Q,

 

 

Multiple Label Read 
(output priority) 

output priority vertical 

default 

,D0S,

 

output priority horizontal 

 

,D0R,

 

 
 
 

Summary of Contents for 520-RF

Page 1: ......

Page 2: ...eil doit s assurer que les rayonnements RF n est pas mis au del de l exigence de Sant Canada Les informations peuvent tre obtenues http www hc sc gc ca ewhsemt pubs radiation radio_guide lignes_direct...

Page 3: ...Data Length 16 Code 93 16 Terminator characters 17 Preamble 17 Postamble 18 Characters 18 Reset 18 DIFFICULT CODE SETUP OPTIONS does not apply to 2D RF Laser 19 Accumulate Mode 1D only 20 Function Co...

Page 4: ...Settings 48 Micro PDF417 Settings 49 Maxi Code Settings 50 QR Code Settings 51 Micro QR Settings 52 Aztec Code Settings 53 Aztec Runes Settings 54 Data Matrix Settings 55 Codablock F Settings 56 Chine...

Page 5: ...lective Reading Settings 67 Collective Reading Settings Continued 68 Read Mode Settings 69 Read Mode Settings Continued 70 Read Mode Settings Continued 71 Read Mode Settings Continued 72 Imager Settin...

Page 6: ...oard so all scanned data will be input to the PC as keyboard data The USB Base Station receiver will work on any computer that supports a USB keyboard PC Mac Linux etc 4 The USB Base Station receiver...

Page 7: ...he USB Base Station will automatically be sensed and the driver installation will begin Windows can usually find the necessary driver on the hard drive under Windows System 32 Drivers occasionally you...

Page 8: ...bstitution etc can cause the 2D RF Laser to no longer pair with the Base It won t affect the existing pairing but it might not allow the 2D RF Laser to pair with a different Base until it is reset to...

Page 9: ...g down the trigger on the RF Laser Scanner for 10 seconds After 10 seconds the data from the last scan will be deleted and the RF Laser Scanner will be able to scan bar codes again Power Modes The 1D...

Page 10: ...u Code 39 UPC EAN Enabled Enabled Check digit disabled UPC supplements disabled Accumulate Mode enabled UPC E Compressed NSC of 0 Caps Lock Off UPC A NSC and EAN 13 1st 2 characters Start stop charact...

Page 11: ...mentary exposure to a laser s low power visible light is not known to be harmful you should not aim the beam into anyone s eyes The important thing to remember about using a laser with the RF Laser Re...

Page 12: ...een when in setup mode 2 Next choose the setting you want to change an option for and scan its code You will hear 2 beeps each time you read a setup barcode 3 Then choose the option you want to change...

Page 13: ...nd Code 128 Enabling Start Stop character transmission means that the RF Laser Reader will transmit the Start Stop characters to your computer along with the data For example data of 1234 would be tra...

Page 14: ...upplement with the UPC EAN providing the UPC has a NSC of 5 or the EAN code has a country code of 99 Without the correct NSC or country code the Code 128 portion will be ignored UPC code with an NSC o...

Page 15: ...rs scan F MSI and Plessey Disable MSI 0 Enable MSI with 1 Mod 10 check digit 1 Enable MSI with 2 Mod 10 check digits 2 Enable MSI with 1 Mod 11 and 1 Mod 10 check digit 3 Transmit No Check Digits 4 Tr...

Page 16: ...omputer along with the bar code data 2 of 5 Data Length 2 of 5 Code is so susceptible to interpreting partial scans as valid reads that the Radio Freedom Reader uses fixed length data as a safeguard T...

Page 17: ...preamble setting scan Clear here instead of scanning SET or any characters from the FULL ASCII MENU You can trim 1 15 leading characters from bar code codes by scanning a tilde ASCII 126 followed by...

Page 18: ...he Postamble trimming and Preamble trimming will be transmitted without trimming Selective trimming and min max bar code data is also supported through Postamble specifications See Preamble above for...

Page 19: ...Scan 1 to select the 4 second beam Scan End Setup To return to the default 2 second beam scan 0 instead of 1 Automobile VIN READING There is special support for reading automobile Vehicle Identificat...

Page 20: ...t reads a bar code without a leading space Then the entire buffer including that last code is transmitted as one long bar code A bar code of a double minus sign clears the buffer Scanning a backspace...

Page 21: ...hift OFF Control On FS Ctrl ON Control Off GS Ctrl OFF Alt On RS Alt ON Alt Off US Alt OFF refers to the keys on the Number pad on the far right side of a PC keyboard To emulate any of the keys above...

Page 22: ...L C Command ON and NULL D Command OFF For the Option Key ON OFF use RS Option On and US Option Off Transmitting any ASCII character using its 3 digit ASCII code You can also transmit any ASCII charact...

Page 23: ...g to read Extra characters at the beginning or end of your bar code data Clear the Preamble and Postamble Poor read rate Get close to the Base Station and try reading the test label following the scan...

Page 24: ...e installation 11 Click Finish Win98 ME 1 Go to the Start menu 2 Go to Settings 3 Select Control Panel 4 Go to System 5 Click on the Device Manager tab 6 Double Click on the USB Human Interface Device...

Page 25: ...1 Code 93 yes page 32 Code 11 no page 33 Industrial 2 of 5 yes page 34 Interleaved 2 of 5 yes page 34 S Code yes page 34 Matrix 2 of 5 no page 34 Chinese Post Matrix 2 of 5 no page 34 MSI Plessey yes...

Page 26: ...page 55 Other Options Item Setup Info Number of Characters page 56 Composite Codes page 57 String Options preamble postamble page 58 String Options prefix suffix page 59 String Options code identific...

Page 27: ...27 Set to factory default To set the scanner to factory defaults scan the code below Reset All 2D Settings to Default...

Page 28: ...ro transmit check digit default E7 UPC E no leading zero not transmit check digit E9 UPC E leading zero transmit check digit E6 UPC E leading zero not transmit check digit E8 UPC A E conversion transm...

Page 29: ...EAN 8 ISSN Conversion disable ISSN conversion default HN enable ISSN conversion HO enable ISSN if possible 4V EAN 13 and EAN 8 ISMN Conversion disable ISMN conversion default IO enable ISMN conversio...

Page 30: ...gies Exclusive Enable Disable EAN 13 no supplement default enable JG JU N A EAN 13 with 2 digit supplement JH JV N A EAN 13 with 5 digit supplement JI JW N A note setting any symbology to exclusive wi...

Page 31: ...armaceutical Check Digit CD not check CD default C1 check CD C0 not transmit CD D8 transmit CD default D9 Code 39 and It Pharmaceutical Misc Settings not transmit start stop default D1 transmit start...

Page 32: ...Conversion enable only Codabar normal mode default HA enable only ABC code H4 enable only CX code H5 enable Codabar ABC and CX H3 Codabar Check Digit CD not check CD default H7 check CD H6 not transmi...

Page 33: ...r HC minimum data three characters HB minimum data five characters default HF Codabar Space Insertion disable space insertion default HE enable space insertion HD Codabar Inter Character Gap Check dis...

Page 34: ...te setting any symbology to exclusive will disable all other symbologies Code 128 and GS1 128 EAN 128 EAN 128 Conversion disable GS1 128 default OF enable GS1 128 only JF enable EAN 128 if possible OG...

Page 35: ...p ZZ ZZ Code 93 Settings Symbology Exclusive Enable Disable Code 93 default enable A5 B5 VD note setting any symbology to exclusive will disable all other symbologies Code 93 Check Digit CD not transm...

Page 36: ...e Enable Disable Code 11 default disable BLB BLC BLA note setting any symbology to exclusive will disable all other symbologies Code 11 Check Digit CD not check CD BLF check 1 CD BLG check 2 CD BLH ch...

Page 37: ...mbology to exclusive will disable all other symbologies 2 of 5 and S Code Check Digit CD not check CD default G0 check CD G1 not transmit CD E1 transmit CD default E0 2 of 5 and S Code Space Check dis...

Page 38: ...symbology to exclusive will disable all other symbologies MSI Plessey Check Digit CD not check CD 4A check 1 CD mod 10 default 4B check 2 CD mod 10 mod 10 4C check 2 CD mod 10 mod 11 4D check 2 CD mod...

Page 39: ...A1 B1 VA note setting any symbology to exclusive will disable all other symbologies UK Plessey Check Digit CD not transmit CD 4O transmit CD default 4N UK Plessey Space Insertion disable space inserti...

Page 40: ...0 POSTNET Start Setup End Setup ZZ ZZ POSTNET Settings Symbology Exclusive Enable Disable POSTNET default disable D6C D6A D6B note setting any symbology to exclusive will disable all other symbologies...

Page 41: ...il Bar Code Start Setup End Setup ZZ ZZ Intelligent Mail Bar Code Settings Symbology Exclusive Enable Disable IMBC default disable D5H D5F D5G note setting any symbology to exclusive will disable all...

Page 42: ...Limited default enable JJ JY SK GS1 DataBar Expanded Expanded Stacked default enable JK DR SL GS1 DataBar All Above Types default enable BC6 BCI BCU note setting any symbology to exclusive will disab...

Page 43: ...fault disable JL WH WI note setting any symbology to exclusive will disable all other symbologies Korean Postal Authority Check Digit CD not transmit CD default transmit CD Korean Postal Authority Das...

Page 44: ...IATA default enable A4 B4 VH note setting any symbology to exclusive will disable all other symbologies IATA Check Digit CD not check CD default 4H check FC SN only 4I check FC CPN SN 4J check FC CPN...

Page 45: ...Tri Optic Start Setup End Setup ZZ ZZ Tri Optic Settings Symbology Exclusive Enable Disable Tri Optic default enable JD JZ N A note setting any symbology to exclusive will disable all other symbologi...

Page 46: ...ZZ ZZ Telepen Settings Symbology Exclusive Enable Disable Telepen default enable A9 B9 VG note setting any symbology to exclusive will disable all other symbologies Telepen Conversion Output Mode nume...

Page 47: ...PN Customer Bar Code Start Setup End Setup ZZ ZZ JPN Settings Symbology Exclusive Enable Disable JPN default disable D5R D5P D5Q note setting any symbology to exclusive will disable all other symbolog...

Page 48: ...48 PDF417 Start Setup End Setup ZZ ZZ PDF417 Settings Symbology Exclusive Enable Disable PDF417 default enable BC3 BCF BCR note setting any symbology to exclusive will disable all other symbologies...

Page 49: ...PDF417 Start Setup End Setup ZZ ZZ Micro PDF417 Settings Symbology Exclusive Enable Disable Micro PDF417 default enable BC4 BCG BCS note setting any symbology to exclusive will disable all other symb...

Page 50: ...Maxi Code Start Setup End Setup ZZ ZZ Maxi Code Settings Symbology Exclusive Enable Disable Maxi Code default enable BC2 BCE BCQ note setting any symbology to exclusive will disable all other symbolog...

Page 51: ...51 QR Code Start Setup End Setup ZZ ZZ QR Code Settings Symbology Exclusive Enable Disable QR Code default enable BC1 BCD BCP note setting any symbology to exclusive will disable all other symbologies...

Page 52: ...Micro QR Start Setup End Setup ZZ ZZ Micro QR Settings Symbology Exclusive Enable Disable Micro QR default enable D38 D2U D2V note setting any symbology to exclusive will disable all other symbologie...

Page 53: ...tec Code Start Setup End Setup ZZ ZZ Aztec Code Settings Symbology Exclusive Enable Disable Aztec Code default enable BC5 BCH BCT note setting any symbology to exclusive will disable all other symbolo...

Page 54: ...c Runes Start Setup End Setup ZZ ZZ Aztec Runes Settings Symbology Exclusive Enable Disable Aztec Runes default disable BF4 BF2 BF3 note setting any symbology to exclusive will disable all other symbo...

Page 55: ...ZZ ZZ Data Matrix Settings Symbology Exclusive Enable Disable Data Matrix ECC 200 default enable BC0 BCC BCO Data Matrix ECC 000 140 default disable BG2 BG0 BG1 note setting any symbology to exclusiv...

Page 56: ...block F Start Setup End Setup ZZ ZZ Codablock F Settings Symbology Exclusive Enable Disable Codablock F default disable D4R D4P D4Q note setting any symbology to exclusive will disable all other symbo...

Page 57: ...de Start Setup End Setup ZZ ZZ Chinese Sensible Code Settings Symbology Exclusive Enable Disable Chinese Sensible Code default disable D4K D4L D4M note setting any symbology to exclusive will disable...

Page 58: ...t disable BCB BCN BCZ All 1D and 2D Codes default disable A0 B0 note setting any symbology to exclusive will disable all other symbologies Use this setting if you re having trouble reading a bar code...

Page 59: ...imum number of characters allowed The character length settings can be global applying to all enabled codes or individual applying only to selected code types Character Length Settings Global Setting...

Page 60: ...fault D1W enable EAN UPC composite D1V Composite Component enable 1D composite only BL0 enable 2D composite only BL1 enable 1D and 2D composites default BL2 Outputs for Composite Code Setting Composit...

Page 61: ...to 4 digits Specified strings can be added in front and at the end of the data for a specific symbology By default the prefix is empty and the suffix is a CR character 3 Code Identification Code Leng...

Page 62: ...M1 O1 EAN 13 N3 N8 EAN 13 add on M2 O2 EAN 8 N4 N9 EAN 8 add on M3 O3 Code 39 M4 O4 Tri optic MC PN Codabar M5 O5 Industrial 2 of 5 M6 O6 Interleaved 2 of 5 M7 O7 S code MB OB Matrix 2 of 5 GL GM IAT...

Page 63: ...Matrix MD PO Aztec BF0 BF1 Chinese Sensible Code D4N D4O QR Code MK PW Maxicode ML PX PDF417 OC PY MicroPDF417 OD PZ Clear Prefix Suffix MG PR Prefix Suffix Example Programming Sequence 1 Scan Start S...

Page 64: ...5F F 0F f F ENQ 1E 5G G 0G g G ACK 1F 5H H 0H h H BEL 1G 5I I 0I i I BS 1H 5J J 0J j J HT 1I 5K K 0K k K LF 1J 5L L 0L l L VT 1K 5M M 0M m M FF 1L 5N N 0N n N CR 1M 5O O 0O o O SO 1N 5P P 0P p P SI 1O...

Page 65: ...6 digit 3 code length 1D 2D 6 6 digit 6 Code Identification and Code Length can be included in a prefix and or suffix The code length will be the number of characters that is configured above The cod...

Page 66: ...5 M Intelligent Mail Bar Code 0 EAN 8 A POSTNET 3 EAN 8 2 J GS1 DataBar y EAN 8 5 K Composite Code A m Code 39 V Composite Code B n Code 39 Full ASCII W Composite Code C l Italian Pharmaceutical Y Cod...

Page 67: ...iple Label Read multiple label 1 default D01 multiple label 2 D02 multiple label 3 D03 multiple label 4 D04 multiple label 5 D05 multiple label 6 D06 multiple label 7 D07 multiple label 8 D08 multiple...

Page 68: ...during multiple read default D0T enable same label read during multiple read D0U Sorting Labels enable sorting decoded labels default D0V disable sorting decoded labels D0W Buffered Mode buffered mod...

Page 69: ...tput However when the scanner cannot decode any labels for some configurable time it will forget the previous scan and then the same label can be read again Multiple Read Reset Time multiple read rese...

Page 70: ...igger switch the read time configured for normal reading will be used for auto trigger read time Auto Trigger Read Time read time 1 second default F read time 2 seconds G read time 3 seconds H read ti...

Page 71: ...ely YL Redundancy read 1 time redundancy 0 X0 read 2 time redundancy 1 default X1 read 3 time redundancy 2 X2 read 4 time redundancy 3 X3 read 5 time redundancy 4 BS read 6 time redundancy 5 BT read 7...

Page 72: ...code without an add on is read Margin Check Quiet Zone no margin check YN margin check 1 7 normal YO margin check 2 7 normal YP margin check 3 7 normal YQ margin check 4 7 normal YR margin check 5 7...

Page 73: ...e good for hard to read codes DM3 standard mode default DM2 semi quick mode DM1 quick mode good for easy to read codes DM0 LCD Display Scanning disable scanning from LCD display default D3I enable sca...