AUDEMAT FM Probe 1.2.x User Manual
–
07/2021
Page 40
WorldCast Systems SAS - 20, avenue Neil Armstrong
–
33700 Merignac
–
Bordeaux Métropole (France)
+33 (0)5 57 928 928
–
–
www.worldcastsystems.com
demodulate up to 8 frequencies.
This is the standard mode when more than 3 receivers are enabled (license option).
Attenuation can be applied individually to the 3 tuners.
Streaming:
Set the streaming code and the rate for MP3 streaming if applicable.
Vuemeter thresholds:
Vuemeters are available on the Overview page and on the Manage Channels page.
They are green when below thresholds, orange when above alert threshold and red when over alarm threshold.
Date and time:
Date, time and time zone can be updated by clicking the Change button.
NTP (Network Time Protocol):
The user can enter a time server address to update the IP board clock automatically. Make sure this address can be
reached by the unit; specifically, the gateway must be properly set. Specify whether it should be synchronized
continuously or periodically. For periodic synchronization, indicate what time the daily synchronization should occur
(between 0 and 23).
Several servers may be set. Simply enter the various addresses separated with commas.
SysLog:
Monitoring events recorded in the event log can be sent to a syslog server.
Enable the function and enter your syslog server information in this section.
Administration:
The unit can be restarted and values set back to factory settings.
!
When resetting the unit, do not forget to set the time!
When a new AUDEMAT FM Probe software release is available, you may receive the update patch file from your
WorldCast Systems dealer.
Click the Select button to locate it, and once selected, click the Apply button. After the upload process is done, check
on this page that the new release is uploaded.
Backup and restore:
The system configuration (which includes the monitoring configuration) and the ScriptEasy script can be backed up,
for instance to be used in a second unit.
The backup file is saved in the download directory with the name:
RadioProbe_
Version number_Serial number_date_time
.cnf
Before restoring data, select the parts you want to restore, then click on the Restore button to select the backup file