background image

2

English

   Description

World Dryer high performance recess mounted, ADA compliant warm air hand dryer, powered by a high speed universal motor, 

delivering 2300 Watts of drying power. This hand dryer runs on 115 Volts AC or 208/220-240 Volts AC electrical supply, depending on 

model. Automatic and push-button models are represented in this product group. This appliance is intended for use in hand drying, 

contributing to fast, hygienic and cost effective hand sanitation. This hand dryer may be used in commercial, industrial, office and 
public facility environments.

   General Specifications 

   Electrical Specifications

(cULus Listed, E19860, CE TUV-GS)

  General Safety Information

       

DANGER

 

• Always disconnect the power source before servicing or installing the hand dryer.

       

DANGER

• This hand dryer must be properly grounded (Earthed) for safe operation. An identified ground connection point is supplied on the

hand dryer’s wall base.

• We recommend GFCI protection in wet or damp locations or as required by local code.

       

WARNING

• Use only the electrical power (voltage and frequency) specified for the model hand dryer being installed.

• Connect the hand dryer to the nearest suitable distribution panel.

• To limit a voltage drop, and insure efficient operation, use wire gauge as required by local or National Electrical Code.

• Do not connect to a branch circuit with CB or fuse protection over 20 Amps. This is in compliance with The National Electrical Code.

• All automatic model hand dryers must have a dedicated 20 Amp circuit as required by Underwriters Laboratories, Inc. (UL).

• Route all field wiring away from any moving parts within the hand dryer.

Unpacking

1. Remove all packing material. Recycling is recommended.

2. Carefully remove the hand dryer from the shipping carton, using care not to drop the appliance.

3. Inspect carefully for any damage that may have occurred during transit. Check for any loose, missing or damaged parts. If the

hand dryer is damaged, promptly inform the shipper or dealer where you purchased it.

Models

Nozzle

Drying Cycle

Dimensions (WxDxH)

Weight

Cover Material

XRM

Fixed

Automatic

13.1” x 13.8” x 4”   

333 mm x 351 mm x 102 mm

26.5 lbs / 12 kgs

Stainless Steel

XRM

Fixed

Automatic

13.1” x 13.8” x 4”   

333 mm x 351 mm x 102 mm

35 lbs / 15.9 kgs

Cast Iron

RM

Fixed

20 Seconds

13.1” x 13.8” x 4”   

333 mm x 351 mm x 102 mm

35 lbs / 15.9 kgs

Cast Iron

Failure to disconnect the power source before installation or servicing can 

result in serious injury or death from electric shock. 

Failure to properly ground this unit could result in severe electrical shock 

and/or death. 

Risk of fire, personal injury or property damage are possible if local codes, 

NEC codes or safety recommendations are not followed.

Models

Type

Electrical Input

Amperage

Watts

XRM5

Automatic

115 VAC, 60 Hz

20

2300

RM5

Push-button

115 VAC, 60 Hz

20

2300

XRM54

Automatic

208-230 VAC, 60 Hz

10

2300

RM54

Push-button

208-230 VAC, 60 Hz

10

2300

XRM548

Automatic

220-240 VAC, 50 Hz

10

2300

RM548

Push-button

220-240 VAC, 50 Hz

10

2300

CAUTION

  

Improper mounting could result in personal injury or property damage.

WARNING

 

 

Cancer and Reproductive Harm - www.p65warnings.ca.gov

Summary of Contents for AirMax RM Series

Page 1: ...osamente antes de tratar de montar instalar operar o dar mantenimiento al producto aqu descrito Prot jase usted mismo y a los dem s observando toda la informaci n de seguridad No seguir las instruccio...

Page 2: ...ryers must have a dedicated 20 Amp circuit as required by Underwriters Laboratories Inc UL Route all field wiring away from any moving parts within the hand dryer Unpacking 1 Remove all packing materi...

Page 3: ...udes avoiding switched lighting circuits or other circuits where equipment may be switched on off 9 Provide a minimum length of 24 61cm of wire in the wall box to allow easy connection to the dryer te...

Page 4: ...and Dryers Parts List For Repair Parts visit www WorldDryer com Please provide following information Model number Serial number Part description and number shown in parts list 24 3 8 6 4 5 17 20 19 21...

Page 5: ...ll Cast Iron Push button with Mtg Hardware RM All 194 3K 1 r13 Inlet Grill Cast Iron Automatic with Mtg Hardware XRM All 194 3XRAK 1 14 Tamper Proof Cover Screw Cast Iron Covers XRM RM All 100B3 1 14...

Page 6: ...e inch replace brushes See replacement instructions 8 Replace cover Place cover squarely over base and push flush to wall Insert 2 cover mounting screws and tighten until snug Do not over tighten REPL...

Page 7: ...7 English Wiring Diagram Wiring Diagram Model RM5 Wiring Diagram Model XRM5 Wiring Diagram Model RM54 Wiring Diagram Model XRM54 Wiring Diagram Model RM548 Wiring Diagram Model XRM548...

Page 8: ...which proves to be defective within limited warranty For any product believed to be defective within limited warranty first write or call dealer from whom the product was purchased Dealer will give ad...

Page 9: ...anos deben tener un circuito dedicado de 20 amperios para satisfacer los requisitos de Underwriters Laboratories Inc UL Encamine todo el cableado realizado durante la instalaci n lejos de todas las pa...

Page 10: ...tados de luces ni ning n otro circuito al que est n conectados artefactos con interruptor 9 El conductor debe tener al menos 61 cm de longitud en la caja de embutir para facilitar la conexi n de los t...

Page 11: ...ara informaci n sobre repuestos visite www WorldDryer com Por favor proporcione la siguiente informaci n N mero de modelo N mero de serie Descripci n de la pieza y n mero indicados en la lista de part...

Page 12: ...e montaje RM todos 194 3K 1 r13 Rejilla de entrada fundici n funcionamiento autom tico con torniller a de montaje XRM todos 194 3XRAK 1 14 Tornillo resistente a manipulaciones para la cubierta cubiert...

Page 13: ...e la base y presi nela hasta que est al ras contra la pared Inserte dos 2 tornillos de montaje de la cubierta y apri telos hasta que est n ajustados No los apriete demasiado REEMPLAZO DE LAS ESCOBILLA...

Page 14: ...de manera de evitar las piezas m viles Attention Acheminer les fils l cart des pi ces mobiles L1 L2 N E L1 L2 N E Diagrama de Cableado Modelo XRM54 Conductor blanco Elemento calefactor L1 L1 L2 N L1 L...

Page 15: ...tura y describa la naturaleza del defecto La propiedad del art culo y el riesgo de p rdida pasan al comprador en el momento de la entrega del art culo a la compa a de transporte Si el producto se da a...

Page 16: ...tous les mod les automatiques de s che mains doivent tre install s sur un circuit d di de 20 amp res Faire passer l ensemble du c blage sur site l cart des pi ces mobiles qui sont l int rieur du s che...

Page 17: ...n Il faut donc galement viter les circuits d clairage interrupteurs ou d autres circuits o les quipements peuvent tre allum s ou teints 9 Laisser d passer une longueur de c ble minimale de 61 cm de la...

Page 18: ...des pi ces Pour les pi ces d tach es consulter www WorldDryer com Fournir les renseignements suivants Num ro de mod le Num ro de s rie Description et num ro de la pi ce figurant sur la liste des pi c...

Page 19: ...nt RM tous 194 3K 1 r13 Grille d entr e fonte automatique avec mat riel correspondant XRM tous 194 3XRAK 1 14 Vis de capot inviolable capots en fonte XRM RM tous 100B3 1 14 Vis de capot inviolable cap...

Page 20: ...ique Remplacement des balais du moteur 8 Remonter le capot en le pla ant droit sur la base et en le poussant contre le mur Ins rer les deux vis de montage du capot et les serrer jusqu ce qu elles soie...

Page 21: ...e manera de evitar las piezas m viles Attention Acheminer les fils l cart des pi ces mobiles L1 L2 N E L1 L2 N E Sch ma de c blage Mod le XRM54 Fil blanc l ment de chauffage L1 L1 L2 N L1 L2 L1 N Inte...

Page 22: ...ld Dryer en indiquant le nom et l adresse du concessionnaire la date et le num ro de la facture du concessionnaire ainsi que la nature du d faut constat Le titre et le risque de perte passent l achete...

Reviews: