9. ADMINISTRATOR MODE
T TEST
Set the testing temperature and it will be recalculated to appropriate U/I TEST value. If test mode activated, it
will also set the voltage or current to output.
U/I TEST
Set the testing current or voltage and it will be recalculated to appropriate temperature test value. If test mode
activated, it will also set the voltage or current to output.
Figure 9.19: Analog output linear mapping example.
9.7.2 Digital Outputs
Pulse
Set the length for the signal pulse in milliseconds.
Edge
Select the edge of a signal. Either the edge is rising or falling.
Rising edge has the nonactive state at zero and the signal is a change between zero to the supply voltage, thus
the voltage is rising.
Falling edge has the nonactive state at supply voltage and the signal is a change between supply voltage to zero,
thus the voltage is falling.