Supplied By www.heating spares.co Tel. 0161 620 6677
7 181 465 347 (05.01)
48
Replacement of Parts
5.4
Pump
B
Power OFF the appliance.
B
Disconnect the boiler electrical connection.
B
Turn off service cocks.
B
Drain appliance.
B
Remove two top fixing screws from the control box.
B
Lower the control box.
B
Remove screw from underside of right-hand plastic
cover plate.
B
Pull cover plate forwards to remove.
B
Unscrew the pump union nuts.
Fig. 12
After refitting:
B
Fill system, bleed and re-pressurise (see Installation
Instructions).
5.5
Clean condensation trap
In order to prevent spillage of condensate the conden-
sation trap should be completely removed.
B
Screw off the condensation trap and place a suitable
container underneath.
Fig. 13
B
Fill condensation trap with approx. 1/4 l of water and
refit.
5.6
Motor of 3-way diverter valve
(Fig. 14)
B
Power OFF the appliance.
B
Unplug connector from 3-way valve motor.
B
Pull out retaining clip.
B
Remove motor.
1.
1.
2.
3.
4.
5.
7
181
465
330
03
1R
6 720 610 332-72.1R