Supplied By www.heating spares.co Tel. 0161 620 6677
7 181 465 347 (05.01)
30
Rectifying faults
Error EA
10.
Is flue gas CO
2
level incorrect
1)
?
yes:
B
Adjust to correct level.
B
Press
, restart the appliance.
EA?
↓
11.
no:
↓
11.
11.
B
Activate menu option Show service
parameters.
B
Select 5.1 Permanent ignition
(without Gas).
Continuous ignition (without gas) OK?
yes:
B
Press
button to select no.
↓
12.
no:
B
Press
button to select no.
↓
15.
12.
Ignition lead connected to ignition elec-
trodes?
yes:
↓
13.
no:
B
Reconnect lead.
B
Press
, restart the appliance.
EA?
↓
13.
13.
Ignition cable connector engaged in
switchbox?
yes:
↓
14.
no:
B
Power OFF the appliance.
B
Engage ignition cable connector in switchbox.
B
Turn ON the appliance.
B
Press
, restart the appliance.
EA?
↓
14.
14.
Is the ignition electrical wire
damaged?
yes:
B
Power OFF the appliance.
B
Change the ignition electrical wire.
B
Turn ON the appliance.
B
Press
, restart the appliance.
EA?
↓
15.
no:
↓
15.
15.
B
Activate menu option Show service
parameters.
B
Select 3.3 Ionisation current .
Measured ionisation current medium
or high?
yes:
↓
17.
no:
↓
16.
16.
Electrode assembly defective?
B
Power OFF the appliance.
B
Remove electrode assembly.
Electrode assembly burnt out?
yes:
B
Replace electrode assembly.
B
Turn ON the appliance.
B
Press
, restart the appliance.
EA?
↓
17.
no:
B
Refit electrode assembly.
B
Turn ON the appliance.
B
Press
, restart the appliance.
EA?
↓
17.
EA
and
flashing.
During operation: flame not detected
Check
Action