Plume management system
Greenstar Condensfit II – 6 721 819 755 (2019/12)
16
Fig. 39 Plume management 90° elbows offset example
90° Elbows offset dimensions
The plume management kit run must be adequately supported to ensure
it does not separate.
▶ Use support brackets either side of the offset.
Fig. 40 90° elbows offset dimensions
45° Elbows offset dimensions
The plume management kit run must be adequately supported to ensure
it does not separate.
▶ Use support brackets either side of the offset.
Fig. 41 45° elbows offset dimensions
5.4
Plume management Installation
To ease assembly of the flue components, lightly grease the seals with
the solvent-free grease supplied.
▶ Check all the seals are properly seated in the grooves provided and
are in good condition.
▶ All flue joints must be sealed to prevent leakage of condensate and
flue products.
Horizontal plume management runs:
▶ The initial horizontal run from the terminal elbow must have a
minimum 10° fall back, (stop tabs in the elbow prevent less than 10°)
to the appliance for proper disposal of condensate.
▶ Any further horizontal runs after an elbow can be 3°.
NOTICE:
Damage to flue or terminal outlet.
Do not rotate the complete flue terminal assembly.
▶ The flue terminal outlet has built-in stops to limit rotation for
horizontal fluing. This prevents unwanted rain water from entering
the appliance. Do not attempt to force beyond the limit stops.
5.4.1
Installation examples
The plume extensions include a support clamp and are used to support
the plume management system at the joint connection point.
Each support clamp retains one length of Plume management extension.
When assembling multiple lengths of plume management, fully engage
the extension and then withdraw the tube approximately 10mm to allow
for expansion and contraction during operation and expansion due to
weather conditions.
Support clamp fitting
Support clamp (
figure 42)
▶ Mark the position [1] for the wall clamp [2] so that it coincides with
the extension tube just below the top fitting (there are tabs [3] that
will position the clamp up against the top fitting). Allow for the 10mm
expansion gap on all joints.
▶ Drill a hole to suit the wall plug and fit the wall plug.
▶ Screw in the support clamp into the wall plug to the distance shown
in figure 42.
Fig. 42 Support clamp fitting
0010013557-001
0010013713-001
183mm
257mm
0010013712-001
82mm
157mm
65 mm
1
2
3
0010013558-001