
5
Comfort I RF
Comfort I– 6720810964 (2014/07)
2.2
RF Room thermostat
The Room thermostat can only be used in conjunction with the
Programmer/Receiver. The Room thermostat displays the
current room temperature and is also used to set a new
temperature set point. This information is transmitted back to
the Programmer/Receiver to control the boiler output to
maintain the desired room temperature.
Setting a new temperature will not have any effect when the
Programmer/Receiver is in an OFF time period, but will be
stored and take effect during the next ON period.
The display is not backlit, this will reduce the drain on battery
power which will maximise the life of the batteries.
Fig. 2
RF Room thermostat
1 Display
▶ Current room temperature in degrees
centigrade ( °C)
▶ New temperature set points when the
knob is being turned
▶ Control fault codes
2 Battery
condition
indicator
The battery condition indicator is
displayed to advise of low battery power,
at this point there is approximately 2
months battery life
3 Burner ON
indicator
This symbol is displayed when the boiler
is heating (can be up to 6 minutes delay)
4 Rotary push
button knob
Press briefly to show the required room
temperature and turn to select new
temperature set point and press to
confirm
5 Current room
temperature
This is displayed until the knob is turned
or pressed
6720810964-02.1Wo
Comfort I RF
1
3
4
5
2