Operation

Comfort I – 6720810964 (2014/07)

4

Operation

The Programmer/Receiver is supplied with factory set default 
ON and OFF times, for central heating (CH) and hot water 
(HW), that are shown in the table below. These time settings 
can be reset according to the homeowner’s requirements via 
the User menu function on the Programmer/Receiver, 

 

section  5.1. The times can be reset to the factory setting via 
the User menu.
The Room thermostat displays the current room temperature 
and is linked by an RF signal to the Programmer/Receiver.

4.1

Programmer/Receiver

During normal operation the display shows:

the operational modes of the central heating and hot water, 
either 

ON

OFF

AUTO

ONCE

 or 

ADV

, press the Central 

heating or DHW 

select

 button to choose either:

ON

 = heating or hot water is permanently on

OFF

 = heating or hot water is permanently off

AUTO

 = programmed times for heating and hot water

ONCE

 = heating or hot water is on from the first 

programmed on time to the last programmed off time

In the Auto mode, press the Advance button once to move 
to the next on or off time, press for a second time to return 
to the current programme

the  current  time  and  day, 

am or pm for the 12 hour time format

Graphical indication of the current time program, the black 
markers indicate half hour time periods. The flashing black 
marker indicates the current time position in the 
programmed sequence, either in the ON or OFF period.

Fig. 10

Display elements

1. Central heating operational status
2. Current day
3. HW operational status
4. Current time
5. Graphical indication of the current time program
6. 24 hour time scale
7. Frost protection - displayed when boiler is set to minimum
8. Burner ON - display when boiler is heating
9. am or pm display - not displayed in 24 hour clock format

Pressing the knob once and releasing during an OFF period will 
display the current temperature setting and when the next ON 
time is scheduled. The example shown below indicates that the 
Central heating is OFF and will not be ON again “until 16:30” (or 
“until 4:30pm” in 12 hour format) and if the temperature drops 
below 5°C the heating will come on. This setting is for frost 
protection and the frost protection symbol will be displayed.

Fig. 11

Heating off

Pressing the knob once and releasing during an ON time will 
display the current temperature setting and when the next OFF 
time is scheduled. The example shown below indicates that the 
Central heating is ON and will not be OFF again “until 22:30” (or 
“until 10:30pm” in 12 hour format) and the temperature has 
been set to 20°C.

Fig. 12

Heating on

06:30

08:30

16:30

22:30

CH

ON

OFF

ON

OFF

HW

ON

OFF

ON

OFF

6720810964-04.1Wo

2

3

4

5

1

pmam

6

9

8

7

6720810964-05.1W

o

pmam

6720810964-06.1W

o

pmam

Summary of Contents for Greenstar Comfort I RF

Page 1: ...structions Radio Frequency Twin Channel Programmer Receiver and Room Thermostat Greenstar Comfort I RF 6720810964 00 1Wo select advance select advance menu For EMS compatible Worcester Greenstar conde...

Page 2: ...on 10 4 1 Programmer Receiver 10 5 Programmer Receiver settings 11 5 1 User 11 5 1 1 Heating 11 5 1 2 Hot water 12 5 1 3 Holiday function 12 5 1 4 Info 12 5 1 5 Setting 12 5 2 Installer 14 5 3 Key loc...

Page 3: ...nderstand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision BS EN 60335 1 2012 Installation commissioning...

Page 4: ...eiver has up to three sets of ON and OFF times that can be set to control central heating and hot water The unit has user and installer menus to allow the setting of the time programs monitoring of sy...

Page 5: ...klit this will reduce the drain on battery power which will maximise the life of the batteries Fig 2 RF Room thermostat 1 Display Currentroomtemperatureindegrees centigrade C Newtemperaturesetpointswh...

Page 6: ...dServicing instructionmanualformountingtheProgrammer Receiverinto the boiler fascia Wall mounted Programmer Receiver Choose a convenient wall location approximately 1 2 metres from the floor to mount...

Page 7: ...r Receiver Installer menu Radio settings Pair The Room thermostat and Programmer Receiver must be in the same mode of pairing The Programmer Receiver Pairing Unpairing function is found under the Inst...

Page 8: ...laying the current room temperature to move to the next higher level press the knob for more than three seconds and when the bars are displayed release the knob To leave the menu and display current r...

Page 9: ...with the Room thermostat contains 2 x countersunk screws 2 x plastic wall plugs Drill the two holes to suit the wall plugs Fit the wall plugs Fit the screws but leave a sufficientamount proud to allo...

Page 10: ...timeprogram the black markers indicate half hour time periods The flashing black marker indicates the current time position in the programmed sequence either in the ON or OFF period Fig 10 Display ele...

Page 11: ...ation is the same Select the desired day s using the knob Press the knob to select the first Heating ON setting The hours flash Turn the knob to select the desired hours setting Press the knob to conf...

Page 12: ...he holiday function Press the menu key for more than three seconds to enter user menus and select Holiday ON will be displayed Press the knob and ON flashes turn the knob to select OFF Press the knob...

Page 13: ...Contrast this function allows you to adjust the contrast of the screen bydefaultitissetto10 The current contrast flashes Turn the knob to select from 0 to 20 the desired level adjusting the contrast...

Page 14: ...lts is displayed with the fault code and occurrence date The fault screens can be scrolled through using the knob If no faults have occurred the text No fault will be displayed b Landlord func This fu...

Page 15: ...g that is RF pairing of the devices in the system Turn the knob to display Unpairing or Pairing IfPairingischosen presstheknobandpairingisdisplayed withadvancingbars whenthepairingbetweenthedevices ha...

Page 16: ...wtemperaturesettingflashingfor three seconds and then OFF flashing for three seconds Low battery The battery symbol indicates the batteries require replacing within two months refer to section 9 1 Bur...

Page 17: ...s a precision temperature gauge meter available the display can be offset by 5 C to compensate The default value is 0 0 C Turn the knob to select E 1 Fig 20 Temperature sensor adjustment Press the kno...

Page 18: ...d a zero will be displayed indicating that no units are connected Press the knob for more than three seconds to return to the previous level rF 1 Press the knob until the three bars are displayed and...

Page 19: ...RF signal or pairing fault All units powered and not showing low battery symbol Repeat pairing A23 1003 Room stat internal sensor failure Internal room temperature sensor out of valid range Replace R...

Page 20: ...eplace the batteries with the same type AAA 1 5V alkaline Fig 22 Low battery indication Battery access To remove the Room thermostat from the wall mounting plate 1 Insert a suitable flat bladed screwd...

Page 21: ...ycled Electrical and electronic equipment Scrap electrical and electronic equipment must be collected separately and returned to an environmentally compatible recycling facility European Directive on...

Page 22: ...22 Comfort I 6720810964 2014 07 Notes...

Page 23: ...23 Comfort I 6720810964 2014 07 Notes...

Page 24: ...0330 123 9779 LITERATURE 0330 123 9119 TRAINING 0330 123 0166 SALES 0330 123 9669 Worcester Bosch Group Cotswold Way Warndon Worcester WR4 9SW Tel 0330 123 9559 Worcester Bosch Group is a brand name...

Reviews: