Pre-Installation
15
Greenstar 8000 Style – 6720883864 (2019/02)
4.3.2
Rooms containing a bath or shower
CAUTION:
Risk of electric shock
▶ Any switch or appliance control using mains electricity must not be
within reach of a person using the bath or shower.
• In all cases the installation
must be in accordance with the latest
amendments to the latest edition of the IET Wiring Regulations
(BS7671)
.
• Check the IP rating of any control units to be used on this appliance.
• Circuit breaking appliances should be used in accordance with the
regulations.
• Figure 10 is for guidance only.
Fig. 10 Bathroom installations
[1]
Zone 1
[2]
Zone 2
[2*]
Without the end wall, zone 2 must extend 600mm from the bath
[A]
600mm radius from the bath or shower
4.3.3
Appliance clearances
Appliance clearances
• The following details covering the installation, service and
maintenance clearances for the appliance.
CAUTION:
Risk of damage to appliance or property
The appliance will overheat if the clearance space around the appliance
is restricted by objects.
▶ Do not restrict this space with the addition of cupboards, shelves etc.
next to or around the appliance.
▶ Do not store any combustible materials on or next to the appliance,
such as clothes, towels, paper or plastic bags.
Fig. 11 Appliance minimum clearances
Table 7
[*]
Height for either 60/100 flue or 80/125 flue
Appliances in compartments
Follow the latest requirements of BS6798 and BS5440 and note:
• Minimum clearances must be maintained.
• An access door is required to install, service and maintain the
appliance and any ancillary equipment.
• If the appliance is installed in an unventilated airing/storage
cupboard, there is no requirement to make a partition between the
appliance and the storage space as long as the minimum clearances
around the appliance are maintained.
0010017086-001
2*
1
2
1
2
2
1
600mm
600mm
600mm
2250mm
2250mm
2*
A
A
A
Minimum clearances
Description
Dimensions (mm)
X
Appliance width
440
Y
Appliance height
780
Z
Appliance depth
365
Installation/Maintenance
1
Overall clearance height
1,150/1,190 *
2
Overall clearance depth
965
3
In front of appliance
600
4
Overall clearance width
450
5
Above the appliance
170/210 *
6
Either side of appliance
5
7
Below the appliance
200
8
Compartment depth
385
9
Appliance to removable door
20
0010012940-001