HEATING SYSTEM CONNECTION
6 720 641 467 (2010/01)
18
7.8
CONNECTING THE HEAT PUMP TO
THE HEATING SYSTEM
B
The heating system pipes must be laid so that they
withstand temperature differences in the heating
water, without the risk of noise or clicking in the
heating system.
To prevent vibrations between the heat pump and the
remaining system:
B
Install the flexible hoses at the inlet and outlet for the
heat pump supplied as standard.
For the connection between the internal unit and the
heat pump, up to 20 m length with a 28 mm diameter
such as Microflex or Ecoflex.
B
Outdoor pipes must be insulated with a material that
cannot absorb moisture, such as Armaflex class 0.
PUMP CURVES
Fig. 18 Heating circuit pump
2000
1500
1000
500
0
[l/h]
0
10
20
30
40
50
1
2
3
[kPA]
6 720 614 056-11.1D