DIMENSIONS, CLEARANCE AND PIPE CONNECTIONS
6 720 641 467 (2010/01)
14
Fig. 13 Back and top view of the internal unit
1
Heating return
2
Heating water inlet (from the heat pump)
3
Heating flow
4
Heating water outlet (towards the heat pump)
6.3
FITTING THE FILTER VALVE
The task of the particle filter is to filter out dirt before it
can enter the heat pump. Accordingly, the supplied filter
valve must always be fitted on the return pipe, between
the HWDU and the outdoor heat pump. It should be
fitted as close to the heat pump as possible and be
horizontal.
347
1
2
3
4
103
152
194
300
420
543
30
558
6 720 616 817-06.1I