18. Operational Flow Diagrams
MAIN SWITCH
ON
Green Light
On
Room
thermostat
and/or mains
programmer
(or link) On
AND
Electronic
facia
programmer
(if fitted) On
AND
ST13 link in
AND
CH control
knob On
CENTRAL
HEATING
DEMAND
CH light On.
Pump On.
Ignition
Sequence.
Burner Light
On.
Three minute
wait
Gas valve Off.
(CH light still
on. Pump still
On)
Over tempera-
ture shut-
down if flow
temperature
5°C above set
value
Two minute
minimum
burner
pressure then
ramp up
pressure over
next one
minute
Modulate gas
to maintain
flow
temperature
set by control
knob
DEMAND
END
Pump
continue four
minutes.
CENTRAL HEATING FUNCTION
AND
AND
AND
DOMESTIC HOT WATER FUNCTION
MAIN SWITCH
ON
Green Light
On
Flow switch
On
(Top open)
DOMESTIC
HOT WATER
DEMAND
(Priority over
CH demand)
HW light On.
Pump On.
Ignition
Sequence.
Burner on
Four second
ramp to max.
gas pressure.
Modulate gas
to maintain
delivered
water
temperature
at value set by
control knob
Ten second
wait
Gas valve Off.
(HW light still
on. Pump still
On)
Over
temperature
shut-down if
water
temperature
8°C above set
value
Burner shut-
down if
primary
temperature
94°C
(until 84°C)
DEMAND
END
Possible
overrun
condition
within next
four minutes
(See next
section)