25
fore every use. Too low an oil level can damage the oil
pump. The correct oil level is approx. 10 to 20 mm below
the oil tank surface.
Note:
The level of oil must be checked when the riving
knife is pulled back. The measuring stick for the oil is
located on the oil tank in the funnelling screw A (Fig. 9)
and has two notches. If the oil level is at the lower notch,
then the oil level is at a minimum. Should this be the
case, oil must be immediately added. The upper notch
indicates the maximum oil level.
When must the oil be changed?
First oil change after 50 operating hours, then every 500
operating hours.
Changing the oil
Fully retract the splitting column.
1
Place the splitter with the two wheels off the floor onto
2
a pallet or something similar.
Carefully tilt the splitter (two people required) to the
3
rear until it comes to lie on the cover plate. Put a cloth
or a board underneath in order to avoid damages.
Put a basin having a volume of at least 8 litres
4
underneath the filler plug A.
Open the filler plug A so that the oil can come off.
5
Place the splitter on its feet again.
6
Fill in 7 litres of new hydraulic oil using a clean
7
funnel.
Retighten the filler plug.
8
Check the oil level after the first switching on.
9
Dispose of the used oil in a correct manner at a public col-
lection facility. It is prohibited to drop old oil on the ground
or to mix it with waste.
We recommend the following hydraulic oils:
Aral Vitam gf 22
"0%NERGOL(,0(-
Mobil DTE 11
Shell Tellus 22
or oils of same quality.
Do not use any other types of oil
as they would influence
the function of the hydraulic cylinder.
Splitting spar
"EFORE USE THE SPAR OF THE SPLITTER MUST BE SLIGHTLY
greased. Repeat this procedure every five operating hours.
Slightly apply grease of oil spray. The spar may never run
dry.
Hydraulic system
The hydraulic unit is a closed system with oil tank, oil
pump and control valve.
The system is complete when the machine is delivered,
and may not be changed or manipulated.
Regularly check the oil level.
Too low an oil level damages the oil pump.
Regularly check the hydraulic connections and bolts for
tightness. Retighten if necessary.