WCD8HG/WCD8HGH
8
Before commissioning
WCD8HG and WCD8HGH are delivered without the console mounted. This must be installed prior to
commissioning. Refer installation instructions, Appendix 1.
Safety
•
Position the dehumidifier on a stable and level surface so that it will not overturn.
•
The air in- and outlets of dehumidifier must not be covered during operation, since this may cause overheating and
give rise to the risk of fire (refer Fig. A)
•
The different models of WCD8HG are stackable, at a height of two, when stored on floors.
•
The dehumidifier must not be transported or rolled in stacked position.
Fig. A Fig. B
Use and operation of the WCD8HG
Location and condensate disposal
Ambient temperature operating range: +3°C to +30°C
Ambient humidity operating range: 40 to 100% RH
If the dehumidifier has been stored at a temperature lower than the ambient, it should be allowed to assume ambient
temperature before it is started. After it has been switched off, the dehumidifier must not be restarted earlier than within
10 minutes.
1.
Position the
dehumidifier in the center of the premises, on a surface that is not sensitive to water.
2.
Shut the doors, windows, vents, etc., so that the premises are as tight as possible. Maintain the highest possible
ambient temperature to ensure maximum
dehumidification.
3.
The condensate collecting container of the dehumidifier has a built-in level switch that will stop the
dehumidification process when the container is full. This is indicated by the LED switching form constant green to
constant red light. The condensate can also be discharged through a hose directly to drain. A ½” hose should be
connected to the tube with a hose clip above the container (refer Fig. B).
4.
When the collecting container has been removed, the dehumidifier will restart. Empty the container and put it back in
position as quickly as possible.
Summary of Contents for WCD8HG
Page 23: ...WCD8HG WCD8HGH 23...