WCD8HG/WCD8HGH
9
Electrical connections
Connect the mains cable to an earthed 230VAC power outlet. Required fuse: Refer overview of range. To start the
WCD8HG dehumidifier, set the switch to position I (see Fig. C). The electronic control system delays start by about 5
seconds.
Fig. C Fig. D
The WCD8HGH dehumidifier incorporate an electric heater and a two-position switch (refer Fig. D).
Position I
Dehumidification
Position II
Dehumidifi heating
The electric heater will be switched off when the preset room temperature has been reached (factory set to 22°C).
The value can be adjusted on the electronic circuit board to between 10°C and 26°C (see the arrow in Fig. E), which
should be carried out by a specialist.
Fig. E
If the ambient temperature is lower than +3 °C or higher than +30 °C, the dehumidifier will stop (indicated by the LED,
refer below). It will restart automatically when the temperature increases/decreases 2 – 3 °C respectively. If frost should
occur on the evaporator, the dehumidifier will automatically be defrosted once an hour.
LED indications
Constant green light
The dehumidifier is operating.
Constant red light
The collecting container is full and should be emptied.
Flashing green light
Ambient temperature too low (see above).
Flashing red light
Ambient temperature too high