PROBLEM
PROBABLE CAUSE
REMEDY
Motor will not start and fuses or
circuit breakers blow.
1.Short circuit in motor or power cord.
2.Incorrect fuses or circuit breakers.
•Take to a qualified service technician.
•Replace with correct fuse or circuit breaker
for the circuit.
Motor fails to reach full power.
1.Overloaded circuit.
2.Improper extension cord.
•Turn off other machines and retry.
•Replace with proper size extension cord.
See ELECTRICAL INFORMATION.
Motor stalls.
1.Short circuit in motor.
2.Incorrect fuses or circuit breakers.
3.Overloaded circuit.
4.Low voltage.
•Take to a qualified service technician.
•Replace with correct fuse or circuit breaker
for the circuit.
•Turn off other machines and retry.
•Check the power line for the proper
voltage. Use another circuit or have a
qualified electrician upgrade the service.