PRE-INSTALLATION INFORMATION
INSTALLING ABOVE 2000 FEET
•
In the USA, the appliance must be derated 4% for every 1,000 ft above 2,000 ft elevations.
•
In Canada, these appliances are certified for altitudes of 0 – 4,500 ft.
ORIFICE SIZES, PRESSURES AND BTUs
NATURAL GAS
PROPANE GAS
Manifold Press: (W.C.)
3.5"
Manifold Press: (W.C.)
10"
Maximum Supply Pressure
10.5"
Maximum Supply Pressure
13"
Minimum Supply Pressure
4.5"
Minimum Supply Pressure
11"
BEFORE YOU START
Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and
immediately inform your dealer if any damage is found. Do not install any unit with damaged, incomplete, or substitute parts.
Check your packing list to verify that all listed parts have been received. You should have the following:
• Fireplace (Firebox and Burner System)
• Log Set
ITEMS REQUIRED FOR INSTALLATION
Tools:
Building Supplies:
• Phillips Screwdriver
• Framing Materials
• Hammer
• Wall Finishing Materials
• Saw and/or saber saw
• Caulking Material (Noncombustible)
• Level
• Fireplace Surround Material (Noncombustible)
• Measuring Tape
• Piping Complying with Local Codes
• Electric Drill and Bits
• Tee Joint
• Pliers
• Pipe Sealant Approved for use with Propane/LPG
• Square
(Resistant to Sulfur Compounds)
• Pipe Wrench
Model
Gas
Orifice Size
Input Max
Input Min
Number
Type
As Shipped
Btu/hr
Btu/hr
6
•
Ember material
DV36CVN-E
Natural
#
27
46
,
5
00
32
,000
DV36CVP-E
Propane
#
44
46
,
500
36
,000
Summary of Contents for DV36CV-E
Page 41: ...41 ILLUSTRATED PARTS LIST 11 1 2 3 4 5 6 7 8 9 10 LOG SET P N M100513...
Page 46: ...127 6...
Page 47: ...127 6...