CHECKING GAS PRESSURE
Figure 34 - Gas Pressure Check at Gas Valve
Do not use open flame to check for gas leaks.
WARNING
1. Check gas type. The gas supply must be the same as
stated on the appliance’s rating decal. If the gas supply
is different from the fireplace, STOP! Do not install the
appliance. Contact your dealer immediately.
gas line and test all gas joints from the gas meter to the
fireplace for leaks. Use a solution of 50/50 water and
soap or a gas sniffer.
4.
To check gas pressures at valve, turn captured screw
counter clockwise 2 or 3 turns and then place tubing
to pressure gauge over test point. Turn unit to high.
See
Figure 34.
After taking pressure reading, be sure and turn
captured screw clockwise firmly to reseal. Do not over
torque. Check test points for gas leaks.
2.
The appliance and its appliance main gas valve must
be disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of 1/2 psi (3.5 kPa).
The appliance must be isolated from the gas supply
piping system by closing its equipment shutoff valve
during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psi
(3.5 kPa).
. After completing gas line connection, purge air from
5.
Outlet Pressure Tap
Pilot Adjustment
Inlet Pressure Tap
3.
To ease installation, a
18
" flex line with manual
shut-off valve has been provided with on this appliance.
Install and attach
1
/2" gas line onto shut-off valve.
27