�����
��� �����
Label all wires prior to disconnection
when servicing controls. Wiring errors
can cause improper and dangerous
operation. Verify proper operation
after servicing.
CAUTION
NOTE: Unplug power cord before servicing. The
blower
is attached to the insert bottom
and back with Velcro. To remove blower
for servicing, pull away from Velcro and
disconnect wires.
FAN ASSEMBLY DIAGRAMS
Speed Control Control Shaft
Locknut
Control
Knob
Switch
Bracket
Blower
Plug-In
Duplex Outlet
Velcro
Strips
Exhaust Port
Screw
Green
Ground
Wire
Spade
Terminals
BLOWER ELECTRICAL DIAGRAM AND INSTALLATION INSTRUCTIONS
Figure
55
-
Fan wire assembly diagram
37
4
1