CHECKING GAS PRESSURE
ELECTRICAL INSTALLATION
ELECTRICAL WIRING
Electrical connections should only be performed by a qualified, licensed electrician. Main
power must be off when connecting to main electrical power supply or performing service.
All wiring shall be in compliance with all local, city, and state codes. The appliance,
when installed, must be electrically grounded in accordance with local codes, or in the
absence of local codes, with the
National Electrical Code ANSI/ NFPA 70 (latest edition)
and
Canadian Electrical Code, CSA C22.1.
WARNING
Label all wires before disconnecting when servicing controls. Wiring errors can cause
improper and dangerous operation.
CAUTION
1. Check gas type. The gas supply must be the same as
stated on the appliance’s rating decal. If the gas supply
is different from the fireplace, STOP! Do not install the
appliance. Contact your dealer immediately.
shut-off valve has been provided with on this appliance.
Install and attach
1
/
2
" gas line onto shut-off valve.
3. After completing gas line connection, purge air from
gas line and test all gas joints from the gas meter to the
fireplace for leaks. Use a solution of 50/50 water and
soap or a gas sniffer.
4.
Figure 34 - Gas Pressure Check at Gas Valve
Do not use open flame to check for gas leaks.
WARNING
5.
The appliance and its appliance main gas valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).
2. T
o ease installation, a
18
"
long
flex line with manual
To check gas pressures at valve, turn captured
screwcounter clockwise 2 or 3 turns and then place
tubing to pressure gauge over test point.
See Figure 34.
After taking pressure reading, be sure and turn captured
screw clockwise firmly to reseal. Do not over torque.
Check test points for gas leaks.
Pressure Test
“IN”
Pressure Test
“OUT”
HI/LO
Knob
Pilot Adjustment
Screw
Control knob
Ignitor
This fireplace requires 110V
AC electrical supply for normal operation in order to power up blower
.
2
7