Maintenance
Hydraulic System
Maintenance
60HDdoc011304
5-16
5
3.
Inspect the hydraulic pump motor brushes every 750 hours of operation. Remove brush
dust and replace the brushes if they worn to a length of 1/4” or shorter
.
CAUTION!
Do not operate the hydraulic system if the pump
motor brushes are worn shorter than
1/4”.
Damage to the
pump motor may result.
4.
Periodically check all hydraulic lines and fitting as needed. Replace as necessary.
750