Initial Start-Up

3.1

Battery Test

Five battery symbol segments ranging from depleted to fully charged 
continuously indicate the current battery level at the main menu.

3.2

Installing and Replacing Batteries

New batteries must be installed before initial start-up, or when 

only one 

solid segment remains in the battery symbol

.

Attention!

!

The instrument must be disconnected from the measuring circuit 
(mains) at all poles before the battery compartment is opened.

Four 1.5 V baby cells in accordance with IEC LR14 are required for 
operation of the METRISO

â

2000

. Use alkaline-manganese batteries only.

Rechargeable NiCd or NiMH batteries can be used as well. Be absolutely 
sure to refer to chapter 12.2, page 22, regarding the charging cycle and 
the charging adapter.
Always replace the batteries in complete sets.
Dispose of batteries in an environmentally sound fashion.

Loosen the two slotted screws at the battery compartment cover on 
the housing rear panel and remove the cover.

Insert four 1.5 V baby cells making certain they are poled in 
accordance with the symbols. Insert the two batteries which are half 
covered by the housing first.

Replace the cover and retighten the screws.

Attention!

!

The instrument may not be operated if the battery compartment 
cover has not been installed and properly tightened!

3.3

Selecting a Menu and Configuring Basic Settings

 

 

Press the 

 or the 

 

key in order to display the desired measuring 

function, the device settings or the database functions.

START

START

Summary of Contents for METRISO 2000

Page 1: ...METRISO 2000 ESD Test Instrument High Resistance Tester for the Measurement of Resistance to Ground and Surface Resistance 3 349 087 53 4 8 01 Operating Instructions...

Page 2: ...functions Right switch contact Displays basic functions scrolling from right to left scrolling from left to right Battery level display finger contact and measurement input Indicator lamps menu driven...

Page 3: ...tance 11 5 4 1 Point to Point Measurement RS with 2 Measuring Probes according to IEC 61340 4 1 DIN IEC 61340 4 1 11 5 4 2 Measuring Surface Resistance RS of Packaging Materials with a Ring Probe in c...

Page 4: ...the METRISO 2000 Resistance to ground surface and volume resistance with special measuring probes Insulation resistance with variable and rising measurement voltage Temperature and relative humidity w...

Page 5: ...can be used as well Be absolutely sure to refer to chapter 12 2 page 22 regarding the charging cycle and the charging adapter Always replace the batteries in complete sets Dispose of batteries in an...

Page 6: ...is switched on Press the key to quit the setup menue Setting On Time Manual Shutdown Activate the Setup key Press the Ton key and then the 10sec 20sec 30sec or 60sec key depend ing upon the desired du...

Page 7: ...back on Contrast can be optimized with the two keys at the far right Press the START key to quit the setup menue The data are saved to memory Setting the Clock Activate the Time key The cursor appears...

Page 8: ...in digital format until the next measuring sequence is started or until the instrument switches itself off automatically If the measuring range upper value is exceeded the upper value is dis played pr...

Page 9: ...ch exceed the selected limit value the red LIMIT LED lights up Select the limit value menu Set the limit value Setting the Limit Value Display the desired numbers and if required the decimal point wit...

Page 10: ...Person to Ground RE System or RG System e g for the measurement of a resistance through the combination of a person shoes flooring system according to ESD STM 97 1 1999 and IEC 61340 4 5 NP Connect th...

Page 11: ...volts The value then displayed is the result Test Voltage according to IEC 61340 5 1 DIN EN 61340 5 1 5 4 2 Measuring Surface Resistance RS of Packaging Materials with a Ring Probe in compliance with...

Page 12: ...value resistance necessitates extremely small measuring current and may be rendered problematic by influences such as electromagnetic fields humidity or surface current A precise test setup is therefo...

Page 13: ...ng Data Display the desired alphanumeric character by pressing the or the key and then select the character with the corresponding softkey Control characters can be entered in the same way and have th...

Page 14: ...alphanumeric character with the or the key and select the desired character with the corresponding softkey Control characters are entered in the same way and have the following meanings reverse and de...

Page 15: ...oon as an individual data record is deleted 6 3 2 Deleting a Memory Address Data Function Select Data Enter blanks to the data fields LOCATION Department Nr and INDEX After all of these fields have be...

Page 16: ...Enter memory address 000 After acknowledgement by pressing button START press at center a safety request appears By simultaneously activating O and K all data that have been saved are deleted from mem...

Page 17: ...en entered exit the data entry window by pressing the softkey If the selected voltage is not within the valid range the cursor jumps back to the entry position for the first digit 7 2 Tests with Risin...

Page 18: ...he housing Then push the adapter down to fix it tightly Press the T R H key The adapter is activated via the interface Select the desired temperature unit of measure C or F with the corresponding key...

Page 19: ...et of batteries alkaline manganese with 10 s on time and performance of one measurement before each automatic instrument shutdown For U f and T FREL 5 hours same conditions as above Measured Quantity...

Page 20: ...gory 600 V CAT III Fouling Factor 2 Electromagnetic Compatibility EMC IEC 61326 EN 61326 Ambient Conditions Nominal Temperature 0 40 C Operating Temperature 10 50 C Storage Temperature 20 60 C without...

Page 21: ...D 12 Maintenance 12 1 Self Test The self test is started from the main menu with the Test key The test has a duration of several seconds The following information is displayed in the two headers Type...

Page 22: ...ries The instrument has been disconnected from the measuring circuit at all poles The voltage selector at the charger has been set to 9 V Connect the NA 0100S battery charger to the charging socket wi...

Page 23: ...WOLFGANG WARMBIER 23...

Page 24: ...nted in Germany Subject to change without notice WOLFGANG WARMBIER Untere Gie wiesen 21 78247 Hilzingen Germany Phone 49 77 31 86 88 0 Fax 49 77 31 86 88 30 e mail info warmbier com http www warmbier...

Reviews: