Applications

ESD protective measures can be tested and documented quickly and 
efficiently with the METRISO

â

2000

 measuring and test instrument within 

your EPA (Electrostatic Protected Area).

The test instrument is especially well suited:

For the selection of ESD materials

For the installation of selected protective measures

For periodic testing of protective measures

All relevant measurements in accordance with IEC 61340-5-1 / 5-2,
DIN EN 61340-5-1 and IEC 61340-4-1 can be performed with the 
METRISO

â

2000

.

Included with the METRISO

â

2000

 Measurement Kit (7100.2000.MK):

High-resistance ohmmeter with integrated infrared interface

Plug-on temperature and humidity sensor

IR interface adapter (RS 232) with data readout software

2 measuring probes according to IEC 61340-4-1

Measuring cables and conductive carrying case with dissipative foam 
inserts

Stored measurement values can be uploaded to a PC for printing and 
archiving via the integrated infrared interface at the METRISO

â

2000

. This 

is especially important where product liability is concerned.

The following measurements and tests can be performed with the 
METRISO

â

2000

:

Resistance to ground, surface and volume resistance
(with special measuring probes)

Insulation resistance
(with variable and rising measurement voltage)

Temperature and relative humidity
(with included, special sensor)

Voltage and frequency

2

Safety Features and Precautions

The METRISO

â

2000

 electronic measuring and test instrument is 

manufactured and tested in accordance with safety regulations 
IEC/EN 61010-1/VDE 0411-1 and EN 61 557.
If used for its intended purpose, the safety of the operator and the 
instrument is assured.

Read the operating instructions carefully and thoroughly before using your 
instrument, and observe all instructions included therein.

The measuring and test instrument may not be used:

If the battery compartment cover has been removed

If external damage is apparent

With damaged connector cables or measuring adapters

If it no longer functions flawlessly

After excessive stress due to transport

After lengthy periods of storage under unfavorable conditions
(e.g. humidity, dust, extreme temperatures)

While the batteries are being charged

Meanings of Symbols on the Instrument

Warning concerning a point of danger
(Attention: observe documentation!)

Protection class II device

CAT I II

Overvoltage category III device

9 V DC charging socket for NA 0100S charging adapter 
(part no. 7100.2000.MK.Z501D)

!

Summary of Contents for METRISO 2000

Page 1: ...METRISO 2000 ESD Test Instrument High Resistance Tester for the Measurement of Resistance to Ground and Surface Resistance 3 349 087 53 4 8 01 Operating Instructions...

Page 2: ...functions Right switch contact Displays basic functions scrolling from right to left scrolling from left to right Battery level display finger contact and measurement input Indicator lamps menu driven...

Page 3: ...tance 11 5 4 1 Point to Point Measurement RS with 2 Measuring Probes according to IEC 61340 4 1 DIN IEC 61340 4 1 11 5 4 2 Measuring Surface Resistance RS of Packaging Materials with a Ring Probe in c...

Page 4: ...the METRISO 2000 Resistance to ground surface and volume resistance with special measuring probes Insulation resistance with variable and rising measurement voltage Temperature and relative humidity w...

Page 5: ...can be used as well Be absolutely sure to refer to chapter 12 2 page 22 regarding the charging cycle and the charging adapter Always replace the batteries in complete sets Dispose of batteries in an...

Page 6: ...is switched on Press the key to quit the setup menue Setting On Time Manual Shutdown Activate the Setup key Press the Ton key and then the 10sec 20sec 30sec or 60sec key depend ing upon the desired du...

Page 7: ...back on Contrast can be optimized with the two keys at the far right Press the START key to quit the setup menue The data are saved to memory Setting the Clock Activate the Time key The cursor appears...

Page 8: ...in digital format until the next measuring sequence is started or until the instrument switches itself off automatically If the measuring range upper value is exceeded the upper value is dis played pr...

Page 9: ...ch exceed the selected limit value the red LIMIT LED lights up Select the limit value menu Set the limit value Setting the Limit Value Display the desired numbers and if required the decimal point wit...

Page 10: ...Person to Ground RE System or RG System e g for the measurement of a resistance through the combination of a person shoes flooring system according to ESD STM 97 1 1999 and IEC 61340 4 5 NP Connect th...

Page 11: ...volts The value then displayed is the result Test Voltage according to IEC 61340 5 1 DIN EN 61340 5 1 5 4 2 Measuring Surface Resistance RS of Packaging Materials with a Ring Probe in compliance with...

Page 12: ...value resistance necessitates extremely small measuring current and may be rendered problematic by influences such as electromagnetic fields humidity or surface current A precise test setup is therefo...

Page 13: ...ng Data Display the desired alphanumeric character by pressing the or the key and then select the character with the corresponding softkey Control characters can be entered in the same way and have th...

Page 14: ...alphanumeric character with the or the key and select the desired character with the corresponding softkey Control characters are entered in the same way and have the following meanings reverse and de...

Page 15: ...oon as an individual data record is deleted 6 3 2 Deleting a Memory Address Data Function Select Data Enter blanks to the data fields LOCATION Department Nr and INDEX After all of these fields have be...

Page 16: ...Enter memory address 000 After acknowledgement by pressing button START press at center a safety request appears By simultaneously activating O and K all data that have been saved are deleted from mem...

Page 17: ...en entered exit the data entry window by pressing the softkey If the selected voltage is not within the valid range the cursor jumps back to the entry position for the first digit 7 2 Tests with Risin...

Page 18: ...he housing Then push the adapter down to fix it tightly Press the T R H key The adapter is activated via the interface Select the desired temperature unit of measure C or F with the corresponding key...

Page 19: ...et of batteries alkaline manganese with 10 s on time and performance of one measurement before each automatic instrument shutdown For U f and T FREL 5 hours same conditions as above Measured Quantity...

Page 20: ...gory 600 V CAT III Fouling Factor 2 Electromagnetic Compatibility EMC IEC 61326 EN 61326 Ambient Conditions Nominal Temperature 0 40 C Operating Temperature 10 50 C Storage Temperature 20 60 C without...

Page 21: ...D 12 Maintenance 12 1 Self Test The self test is started from the main menu with the Test key The test has a duration of several seconds The following information is displayed in the two headers Type...

Page 22: ...ries The instrument has been disconnected from the measuring circuit at all poles The voltage selector at the charger has been set to 9 V Connect the NA 0100S battery charger to the charging socket wi...

Page 23: ...WOLFGANG WARMBIER 23...

Page 24: ...nted in Germany Subject to change without notice WOLFGANG WARMBIER Untere Gie wiesen 21 78247 Hilzingen Germany Phone 49 77 31 86 88 0 Fax 49 77 31 86 88 30 e mail info warmbier com http www warmbier...

Reviews: