14
WOLFGANG WARMBIER
6.2
Saving Measurement Values – STORE Function
➭
Start the respective measurement. The
STORE
key is displayed after
the measurement instead of the
INFO
key.
The
STORE
key is not displayed until after a given amount of time has
elapsed for measurements which are performed without the
START
key. For example, the store key is not displayed after voltage
measurements until a given amount of time has elapsed, so that the
operator can first query the help text with the
INFO
key.
➭
The displayed measurement values are stored to the currently
selected database memory address by briefly acknowledging with
the
STORE
key. The key is briefly displayed as an inverse image during
storage to memory.
➭
Pressing and holding the
STORE
key allows for the entry of a comment,
and storage of the current measurement.
Entering a comment:
Display the desired alphanumeric character with the
or the
key and select the desired character with the corresponding softkey.
Control characters are entered in the same way and have the
following meanings:
¬:
reverse and delete,
¿:
same as the
START
key
After each character has been selected, the cursor moves one posi-
tion to the right. Already entered characters can be deleted in reverse
by pressing and holding any softkey (except for
¿
).
After entry of up to 15 characters, save the measurement values and
the comment by acknowledging with the
START
key (press at center)
.
The following message appears: “Data are stored”.
6.3
Querying Data Records – View Function
➭
Select
View
.
➭
You can scroll forward through the memory addresses with the
key, or backwards with the
key.
➭
After selecting a memory address, the individual data records can be
queried with the
Prev.
and
Next
softkeys, which have been stored to
memory under consecutive numbers.
In case a measurement value is missing for the currently selected location,
perform the measurement and the value will be immediately stored.
START
START
Summary of Contents for METRISO 2000