31
3062165_201508
Roof integration - Mönch-Nonne
Standard dimensions for
determining the position of
the collector array
Min. 3.0
m
Min. 3 rows
Align from left or right
Width incl. skirt
Width incl. visible edging panels
Width incl. visible
edging panels
Width incl. skirt
Top skirts
Top mounting rail
Bottom mounting rail
(with return for flashing tape)
Flashing tape
base, left
Flashing tape
Triangular sealing strip
Edge
protector
Wooden spacer of
15 to 30 mm height to
match to the battens
Screws, nuts,
grub screws,
wood screws in the bag
Intermediate
panels
Connecting rail
Flashing tape
base, right
Right hand
skirt
Left hand skirt
Standard delivery
Assembly components
Number of collectors
1
2
3
4
5
6
7
8
9
10
Width incl. visible edging panels [m]
1.23
2.36
3.49
4.62
5.75
6.88
8.01
9.14
10.27
11.40
Width incl. skirt [m]
1.60
2.73
3.86
4.99
6.12
7.25
8.38
9.51
10.64
11.77
15-60°
For safety reasons, the [German] roofing contractor’s association specifies a
covered substrate with bitumen sheeting or other suitable material below the
collector area to prevent the ingress of moisture in case of leaks. This must
terminate in the roof gutter.
CAUTION