Roof integration - Interlocking tile
Standard delivery
Installation parts
Top skirts
Right hand skirt
Left hand skirt
Top mounting rail
Bottom mounting rail
(with return for flashing tape)
Flashing tape base, right
Flashing tape
base, left
Flashing tape
Triangular
sealing strip
Edge
protector
Wooden spacer of
15 to 30 mm height to
match to the battens
For safety reasons, the [German] roofing contractor’s association specifies a
covered substrate with bitumen sheeting or other suitable material below the
collector area to prevent the ingress of moisture in case of leaks. This must
terminate in the roof gutter.
CAUTION
Screws, nuts,
grub screws,
wood screws in the bag
Intermediate
panels
Connecting rail
Standard dimensions for
determining the position of the
collector array
Position the collector array so that
the roof tiling can be completed as
far as possible using whole or half
tiles, without cutting.
Width of visible
sheet metal
Min. 3
rows
Min. 2.5
m
< 12 cm
Width incl. skirt
< 12 cm
Width incl. visible edging panels
Width incl. skirt
Number of collectors
1
2
3
4
5
6
7
8
9
10
Width incl. visible edging panels [m]
1.23
2.36
3.49
4.62
5.75
6.88
8.01 9.14 10.27 11.40
Width incl. skirt [m]
1.57
2.74
3.87
5.00
6.03
7.26
8.39 9.52 10.65 11.78
Tiles to be removed per
row of tiles:
Skirt width 30 cm
6
10
14
18
22
25
29
33
37
39
Skirt width 30 cm
8
12
18
24
29
35
41
46
52
58
Remove one extra row of tiles
to provide sufficient space for
installing.
30-60°