24
3062165_201508
Roof integration - Slate roof
Standard delivery
Installation parts
Top skirts
Flashing pieces
/ lift plates
Flashing pieces
/ lift plates
Top mounting rail
Bottom mounting rail
(with return for flashing tape)
Flashing tape
base, right
Flashing tape
base, left
Flashing tape
Edge protector
Wooden spacer of
15 to 30 mm height to
match to the battens
Screws, nuts,
grub screws,
wood screws in the bag
Intermediate
panels
Connecting rail
Standard dimensions for
determining the position of
the collector array
Width incl. visible edging panels
Min. 2.7
m
Min. 1
m
Align to the left or right
Width with flashing pieces /
lift plates
Width with flashing pieces / lift plates
Width incl. visible edging panels
Side panel
Side panel
Number of collectors
1
2
3
4
5
6
7
8
9
10
Width incl. visible edging panels [m]
1.23
2.36
3.49
4.62
5.75
6.88
8.01
9.14
10.27 11.40
Width with flashing pieces / lift plates [m]
1.43
2.56
3.69
4.82
5.95
7.08
8.21
9.34
10.47 11.60
15-60°
For safety reasons, the [German] roofing contractor’s association specifies a
covered substrate with bitumen sheeting or other suitable material below the
collector area to prevent the ingress of moisture in case of leaks. This must
terminate in the roof gutter.
CAUTION
Summary of Contents for TopSon F3-1
Page 51: ...51 3062165_201508 Notes...