26
3064300_201703
20. Specification CPM-1-70/7(8), CEW-1-200
DHW cylinder
Type
CEW-1-200
Buffer cylinder
Type
CPM-1-70/7
CPM-1-70/8
Max. operating pressure
bar
3
10
Max. operating temperature
°C
95
95
Cylinder capacity
l
70
180
Continuous cylinder output
t
v
80/60 °C
t
DHW
10/45 °C
kW - l/h
-
20/490
Output factor (heating)
NL60
-
2.9
Output factor (heating)
NL50
-
1.4
Heat-up time 10 kW
10-
50 °C
min
-
59
Draw-off rate, DHW at 40 °C
(T
cyl
= 55 °C, 15 l/min)
l
-
191
Cold water connection
A mm
90
Return, heating / solar
B mm
225/-
222/-
Cylinder sensor, heating / solar
C mm
225/-
590/-
DHW circulation
D mm
-
697
Flow, heating / solar
E mm
352/-
797/-
DHW connection
F mm
-
1194
Electric booster heater (opt.)
G mm
-
-
Thermometer connection
H mm
-
-
Overall height
I mm
740
1270
Diameter incl. insulation
J mm
600
600
Casing width / depth
mm
600 x 650
600 x 650
Service flange
L mm
-
324
Height when tilted
mm
925
1395
Primary heating water
bar/°C
3/95
3/95
Secondary DHW
bar/°C
-
10/95
Internal flange diameter
mm
-
DN 110
Cold water connection
G
½“ fem.
1“ male
Return, heating / solar
G
1 ½“ male / -
1 ½“ male / -
DHW circulation
G
-
¾“ male
Flow, heating / solar
G
1 ½“ male / -
1 ½“ male / -
DHW connection
G
-
1“ male
Protective anode (insulated)
G
-
1 ¼“ fem.
Electric booster heater
G
-
1 ½“ fem.
Cylinder sensor
G
½“ fem.
½“ fem.
Thermometer
G
-
-
Indirect coil surface area,
heating / solar
m²
-
2.3/-
Indirect coil content,
heating / solar
l
-
17/-
Weight
kg
61
62
147
Specification
CEW-1-200
CPM-1-70